Electron Thermometry
- URL: http://arxiv.org/abs/2403.16305v1
- Date: Sun, 24 Mar 2024 21:51:02 GMT
- Title: Electron Thermometry
- Authors: Joost van der Heijden,
- Abstract summary: Performance and accuracy of quantum electronics is substantially degraded when the temperature of the electrons in the devices is too high.
The electron temperature can be reduced with appropriate thermal anchoring and by filtering both the low frequency and radio frequency noise.
Ultimately, for high performance filters the electron temperature can approach the phonon temperature in a dilution refrigerator.
- Score: 0.0
- License: http://creativecommons.org/licenses/by-nc-nd/4.0/
- Abstract: The performance and accuracy of quantum electronics is substantially degraded when the temperature of the electrons in the devices is too high. The electron temperature can be reduced with appropriate thermal anchoring and by filtering both the low frequency and radio frequency noise. Ultimately, for high performance filters the electron temperature can approach the phonon temperature (as measured by resistive thermometers) in a dilution refrigerator. In this application note, the method for measuring the electron temperature in a typical quantum electronics device using Coulomb blockade thermometry is described. This technique is applied to find the readily achievable electron temperature in the device when using the QFilter provided by QDevil. With our thermometry measurements, using a single GaAs/AlGaAs quantum dot in an optimized experimental setup, we determined an electron temperature of 28 $\pm$ 2 mK for a dilution refrigerator base temperature of 18 mK.
Related papers
- On-chip quantum confinement refrigeration overcoming electron-phonon heat leaks [0.0]
We show that a two-dimensional electron gas (2DEG) works as an on-chip heat sink only limited by a fundamental phonon heat-leak.
A single-shot 2DEG cooler can reduce the electron temperature by a factor of two with a hold time up to a second.
arXiv Detail & Related papers (2024-08-21T08:24:58Z) - Low-temperature benchmarking of qubit control wires by primary electron thermometry [32.97208255533144]
We make use of a primary electron thermometry technique, using a Coulomb blockade thermometer, to establish the electron temperature in the millikelvin regime.
We verify the results by also using another electron thermometry technique, based on a superconductor-insulator-normal metal junction.
arXiv Detail & Related papers (2024-03-26T14:03:19Z) - Enhanced Imaging of Electronic Hot Spots Using Quantum Squeezed Light [0.0]
thermoreflective imaging is being used to perform precise temporal and spatial imaging of heat on wires and semiconductor materials.
We apply quantum squeezed light to perform thermoreflective imaging on micro-wires, surpassing the shot-noise limit of classical approaches.
arXiv Detail & Related papers (2024-03-22T16:55:46Z) - An anti-maser for quantum-limited cooling of a microwave cavity [58.720142291102135]
We experimentally demonstrate how to generate a state in condensed matter at moderate cryogenic temperatures.
This state is then used to efficiently remove microwave photons from a cavity.
Such an "anti-maser" device could be extremely beneficial for applications that would normally require cooling to millikelvin temperatures.
arXiv Detail & Related papers (2023-07-24T11:12:29Z) - Millikelvin measurements of permittivity and loss tangent of lithium
niobate [50.591267188664666]
Lithium niobate is an electro-optic material with many applications in microwave signal processing, communication, quantum sensing, and quantum computing.
We present findings on evaluating the complex electromagnetic permittivity of lithium niobate at millikelvin temperatures.
arXiv Detail & Related papers (2023-02-24T22:05:42Z) - A highly-sensitive broadband superconducting thermoelectric
single-photon detector [62.997667081978825]
A thermoelectric detector (TED) converts a finite temperature difference caused by the absorption of a single photon into an open circuit thermovoltage.
Our TED is able to reveal single-photons of frequency ranging from about 15 GHz to about 150 PHz depending on the chosen design and materials.
arXiv Detail & Related papers (2023-02-06T17:08:36Z) - Electron subband degeneracy heat pump for cryogenic cooling [0.0]
An unconventional method of solid-state cryogenic cooling utilizing the electron subband degeneracy of semiconductor heterostructures is discussed in this Letter.
The working principle of using the electrons as the working medium to perform cyclic heat pumping under electrostatic subband "expansion" and "compression" is discussed.
arXiv Detail & Related papers (2022-07-28T17:17:10Z) - Near-monochromatic tuneable cryogenic niobium electron field emitter [48.7576911714538]
We describe electron field emission from a monocrystalline, superconducting niobium nanotip at a temperature of 5.9 K.
The emitted electron energy spectrum reveals an ultra-narrow distribution down to 16 meV.
This source will decrease the impact of lens aberration and enable new modes in low-energy electron microscopy, electron energy loss spectroscopy, and high-resolution vibrational spectroscopy.
arXiv Detail & Related papers (2022-05-11T20:46:21Z) - Measurement of the Low-temperature Loss Tangent of High-resistivity
Silicon with a High Q-factor Superconducting Resonator [58.720142291102135]
We present the direct loss tangent measurement of a high-resist intrinsicivity (100) silicon wafer in the temperature range from 70 mK to 1 K.
The measurement was performed using a technique that takes advantage of a high quality factor superconducting niobium resonator.
arXiv Detail & Related papers (2021-08-19T20:13:07Z) - Adiabatic Sensing Technique for Optimal Temperature Estimation using
Trapped Ions [64.31011847952006]
We propose an adiabatic method for optimal phonon temperature estimation using trapped ions.
The relevant information of the phonon thermal distributions can be transferred to the collective spin-degree of freedom.
We show that each of the thermal state probabilities is adiabatically mapped onto the respective collective spin-excitation configuration.
arXiv Detail & Related papers (2020-12-16T12:58:08Z) - Primary thermometry of propagating microwaves in the quantum regime [0.0]
We propose and experimentally demonstrate thermometry of propagating microwaves using a transmon-type superconducting circuit.
Our device operates continuously, with a sensitivity down to $4times 10-4$ photons/$sqrtmboxHz$ and a bandwidth of 40 MHz.
This thermometry scheme can find applications in benchmarking and characterization of cryogenic microwave setups, temperature measurements in hybrid quantum systems, and quantum thermodynamics.
arXiv Detail & Related papers (2020-03-30T14:48:30Z)
This list is automatically generated from the titles and abstracts of the papers in this site.
This site does not guarantee the quality of this site (including all information) and is not responsible for any consequences.