Exploring the limitations of blood pressure estimation using the photoplethysmography signal
- URL: http://arxiv.org/abs/2404.16049v1
- Date: Tue, 9 Apr 2024 14:08:23 GMT
- Title: Exploring the limitations of blood pressure estimation using the photoplethysmography signal
- Authors: Felipe M. Dias, Diego A. C. Cardenas, Marcelo A. F. Toledo, Filipe A. C. Oliveira, Estela Ribeiro, Jose E. Krieger, Marco A. Gutierrez,
- Abstract summary: Photoplemography (N- Siamese) and Invasive Arterial Blood Pressure (N-IABP) signals are compared.
N-IABP signals meet with AAMI standards for both Systolic Blood Pressure (SBP) and Diastolic Blood Pressure (DBP)
Our findings highlight the potential and limitations of employing PPG for BP estimation.
- Score: 0.0
- License: http://creativecommons.org/licenses/by/4.0/
- Abstract: Hypertension, a leading contributor to cardiovascular morbidity, underscores the need for accurate and continuous blood pressure (BP) monitoring. Photoplethysmography (PPG) presents a promising approach to this end. However, the precision of BP estimates derived from PPG signals has been the subject of ongoing debate, necessitating a comprehensive evaluation of their effectiveness and constraints. We developed a calibration-based Siamese ResNet model for BP estimation, using a signal input paired with a reference BP reading. We compared the use of normalized PPG (N-PPG) against the normalized Invasive Arterial Blood Pressure (N-IABP) signals as input. The N-IABP signals do not directly present systolic and diastolic values but theoretically provide a more accurate BP measure than PPG signals since it is a direct pressure sensor inside the body. Our strategy establishes a critical benchmark for PPG performance, realistically calibrating expectations for PPG's BP estimation capabilities. Nonetheless, we compared the performance of our models using different signal-filtering conditions to evaluate the impact of filtering on the results. We evaluated our method using the AAMI and the BHS standards employing the VitalDB dataset. The N-IABP signals meet with AAMI standards for both Systolic Blood Pressure (SBP) and Diastolic Blood Pressure (DBP), with errors of 1.29+-6.33mmHg for systolic pressure and 1.17+-5.78mmHg for systolic and diastolic pressure respectively for the raw N-IABP signal. In contrast, N-PPG signals, in their best setup, exhibited inferior performance than N-IABP, presenting 1.49+-11.82mmHg and 0.89+-7.27mmHg for systolic and diastolic pressure respectively. Our findings highlight the potential and limitations of employing PPG for BP estimation, showing that these signals contain information correlated to BP but may not be sufficient for predicting it accurately.
Related papers
- Belief Propagation Decoding of Quantum LDPC Codes with Guided Decimation [55.8930142490617]
We propose a decoder for QLDPC codes based on BP guided decimation (BPGD)
BPGD significantly reduces the BP failure rate due to non-convergence.
arXiv Detail & Related papers (2023-12-18T05:58:07Z) - On the Theories Behind Hard Negative Sampling for Recommendation [51.64626293229085]
We offer two insightful guidelines for effective usage of Hard Negative Sampling (HNS)
We prove that employing HNS on the Personalized Ranking (BPR) learner is equivalent to optimizing One-way Partial AUC (OPAUC)
These analyses establish the theoretical foundation of HNS in optimizing Top-K recommendation performance for the first time.
arXiv Detail & Related papers (2023-02-07T13:57:03Z) - Journaling Data for Daily PHQ-2 Depression Prediction and Forecasting [47.93070579578704]
We explore the potential of using actively-collected data to predict and forecast daily PHQ-2 scores on a newly-collected longitudinal dataset.
We obtain a best MAE of 1.417 for daily prediction of PHQ-2 scores, which specifically in the used dataset have a range of 0 to 12.
This illustrates the additive value that can be obtained by incorporating actively-collected data in a depression monitoring application.
arXiv Detail & Related papers (2022-05-06T17:47:05Z) - OpenKBP-Opt: An international and reproducible evaluation of 76
knowledge-based planning pipelines [48.547200649819615]
We establish an open framework for developing plan optimization models for knowledge-based planning (KBP) in radiotherapy.
Our framework includes reference plans for 100 patients with head-and-neck cancer and high-quality dose predictions from 19 KBP models.
arXiv Detail & Related papers (2022-02-16T19:18:42Z) - A Theoretical View of Linear Backpropagation and Its Convergence [55.69505060636719]
Backpropagation (BP) is widely used for calculating gradients in deep neural networks (DNNs)
Recently, a linear variant of BP named LinBP was introduced for generating more transferable adversarial examples for performing black-box attacks.
We provide theoretical analyses on LinBP in neural-network-involved learning tasks, including adversarial attack and model training.
arXiv Detail & Related papers (2021-12-21T07:18:00Z) - BP-Net: Efficient Deep Learning for Continuous Arterial Blood Pressure
Estimation using Photoplethysmogram [0.06524460254566904]
Blood pressure is one of the most influential bio-markers for cardiovascular diseases and stroke.
Current cuffless approaches to continuous BP monitoring involve explicit feature engineering surrounding Photoplethysmogram signals.
We present an end-to-end deep learning solution, BP-Net, that uses PPG waveform to estimate Systolic BP (SBP), Mean Average Pressure (MAP), and Diastolic BP (DBP) through intermediate continuous Arterial BP (ABP) waveform.
arXiv Detail & Related papers (2021-11-29T14:43:58Z) - A Shallow U-Net Architecture for Reliably Predicting Blood Pressure (BP)
from Photoplethysmogram (PPG) and Electrocardiogram (ECG) Signals [1.1695966610359496]
Most existing methods used in the hospitals for continuous monitoring of Blood Pressure (BP) are invasive.
In this study, we explored the applicability of autoencoders in predicting BP from non-invasively collectible signals such as Photoplethysmogram ( PPG) and ECG signals.
It was found that a very shallow, one-dimensional autoencoder can extract the relevant features to predict the SBP and DBP with the state-of-the-art performance on a very large dataset.
arXiv Detail & Related papers (2021-11-12T19:34:20Z) - A Deep Learning Approach to Predict Blood Pressure from PPG Signals [10.028103259763352]
Blood Pressure (BP) is one of the four primary vital signs indicating the status of the body's vital (life-sustaining) functions.
We propose an advanced data-driven approach that uses a three-layer deep neural network to estimate BP based on PPG signals.
arXiv Detail & Related papers (2021-07-30T22:45:34Z) - Ambulatory blood pressure monitoring versus office blood pressure
measurement: Are there sex differences? [55.41644538483948]
Office Blood Pressure Measurement (OBP) is a technique performed in-office with the sphygmomanometer, while Ambulatory Blood Pressure Monitoring (ABPM) is a technique that measures blood pressure during 24h.
The aim of this study is to examine the possible influence of sex on the discrepancies between OBP and ABPM in 872 subjects with known or suspected hypertension.
arXiv Detail & Related papers (2021-06-04T10:09:44Z) - Assessment of deep learning based blood pressure prediction from PPG and
rPPG signals [2.624902795082451]
This work aims to analyze the PPG- and r-based BP prediction error with respect to the underlying data distribution.
We train established neural network (NN) architectures and derive an appropriate parameterization of input segments drawn from continuous PPG signals.
Second, we apply this parameterization to a larger PPG dataset and train NNs to predict BP.
Third, we use transfer learning to train the NNs for r-based BP prediction. The resulting performances are similar to the PPG-only case.
arXiv Detail & Related papers (2021-04-15T15:56:58Z) - Continuous Monitoring of Blood Pressure with Evidential Regression [19.92542487970484]
Photoplethysmogram (MIC) signal-based blood pressure estimation is a promising candidate for modern BP measurements.
The proposed method provides the reliability of the predicted BP by estimating its uncertainty to help diagnose medical condition.
arXiv Detail & Related papers (2021-02-06T09:09:31Z)
This list is automatically generated from the titles and abstracts of the papers in this site.
This site does not guarantee the quality of this site (including all information) and is not responsible for any consequences.