Non-invasive magnetocardiography of living rat based on diamond quantum sensor
- URL: http://arxiv.org/abs/2405.02376v1
- Date: Fri, 3 May 2024 12:12:54 GMT
- Title: Non-invasive magnetocardiography of living rat based on diamond quantum sensor
- Authors: Ziyun Yu, Yijin Xie, Guodong Jin, Yunbin Zhu, Qi Zhang, Fazhan Shi, Fang-yan Wan, Hongmei Luo, Ai-hui Tang, Xing Rong,
- Abstract summary: We present a high-sensitivity, room-temperature Magnetocardiography (MCG) system based on the negatively charged Nitrogen-Vacancy (NV) centers in diamond.
The magnetic cardiac signal of a living rat, characterized by an approximately 20 pT amplitude in the R-wave, is successfully captured through non-invasive measurement.
- Score: 5.49876967816264
- License: http://creativecommons.org/licenses/by/4.0/
- Abstract: Magnetocardiography (MCG) has emerged as a sensitive and precise method to diagnose cardiovascular diseases, providing more diagnostic information than traditional technology. However, the sensor limitations of conventional MCG systems, such as large size and cryogenic requirement, have hindered the widespread application and in-depth understanding of this technology. In this study, we present a high-sensitivity, room-temperature MCG system based on the negatively charged Nitrogen-Vacancy (NV) centers in diamond. The magnetic cardiac signal of a living rat, characterized by an approximately 20 pT amplitude in the R-wave, is successfully captured through non-invasive measurement using this innovative solid-state spin sensor. To detect these extremely weak biomagnetic signals, we utilize sensitivity-enhancing techniques such as magnetic flux concentration. These approaches have enabled us to simultaneously achieve a magnetometry sensitivity of 9 $\text{pT}\cdot \text{Hz}^{-1/2}$ and a sensor scale of 5 $\text{mm}$. By extending the sensing scale of the NV centers from cellular and molecular level to macroscopic level of living creatures, we have opened the future of solid-state quantum sensing technologies in clinical environments.
Related papers
- A spin-refrigerated cavity quantum electrodynamic sensor [1.6713959634020665]
Quantum sensors based on solid-state defects, in particular nitrogen-vacancy centers in diamond, enable precise measurement of magnetic fields, temperature, rotation, and electric fields.
We introduce a cavity quantum electrodynamic (cQED) hybrid system operating in the strong coupling regime, which enables high readout fidelity of an NV ensemble.
We demonstrate a broadband sensitivity of 580 fT/$sqrtmathrmHz$ around 15 kHz in ambient conditions.
arXiv Detail & Related papers (2024-04-16T14:56:50Z) - All-Optical Nuclear Quantum Sensing using Nitrogen-Vacancy Centers in
Diamond [52.77024349608834]
Microwave or radio-frequency driving poses a significant limitation for miniaturization, energy-efficiency and non-invasiveness of quantum sensors.
We overcome this limitation by demonstrating a purely optical approach to coherent quantum sensing.
Our results pave the way for highly compact quantum sensors to be employed for magnetometry or gyroscopy applications.
arXiv Detail & Related papers (2022-12-14T08:34:11Z) - DC Quantum Magnetometry Below the Ramsey Limit [68.8204255655161]
We demonstrate quantum sensing of dc magnetic fields that exceeds the sensitivity of conventional $Tast$-limited dc magnetometry by more than an order of magnitude.
We used nitrogen-vacancy centers in a diamond rotating at periods comparable to the spin coherence time, and characterize the dependence of magnetic sensitivity on measurement time and rotation speed.
arXiv Detail & Related papers (2022-03-27T07:32:53Z) - Investigation and comparison of measurement schemes in the low frequency
biosensing regime using solid-state defect centers [58.720142291102135]
Solid state defects in diamond make promising quantum sensors with high sensitivity andtemporal resolution.
Inhomogeneous broadening and drive amplitude variations have differing impacts on the sensitivity depending on the sensing scheme used.
We numerically investigate and compare the predicted sensitivity of schemes based on continuous-wave (CW) optically detected magnetic resonance (ODMR) spectroscopy, pi-pulse ODMR and Ramsey interferometry.
arXiv Detail & Related papers (2021-09-27T13:05:23Z) - Millimetre-scale magnetocardiography of living rats using a solid-state
quantum sensor [1.0264250032103253]
A key challenge in cardiology is the non-invasive imaging of electric current propagation occurring in the cardiovascular system at an intra-cardiac scale.
Here we demonstrate millimetre-scale magnetocardiography of living rats using a solid-state quantum sensor based on nitrogen-vacancy centres in diamond.
arXiv Detail & Related papers (2021-05-25T05:27:52Z) - Laser threshold magnetometry using green light absorption by diamond
nitrogen vacancies in an external cavity laser [52.77024349608834]
Nitrogen vacancy (NV) centers in diamond have attracted considerable recent interest for use in quantum sensing.
We show theoretical sensitivity to magnetic field on the pT/sqrt(Hz) level is possible using a diamond with an optimal density of NV centers.
arXiv Detail & Related papers (2021-01-22T18:58:05Z) - Detection of biological signals from a live mammalian muscle using a
diamond quantum sensor [41.91891973513696]
We show an alternative technique for detecting magnetic fields generated by the current from action potentials in living tissue using nitrogen vacancy centres in diamond.
We show these measurements can be performed in an ordinary, unshielded lab environment and that the signal can be easily recovered by digital signal processing techniques.
arXiv Detail & Related papers (2020-08-03T16:40:44Z) - Biocompatible technique for nanoscale magnetic field sensing with
Nitrogen-Vacancy centers [0.0]
Nitrogen-vacancy centers in diamonds can be used to measure nanoscale magnetic fields.
The sensitivity at different optical powers is studied to extend this technique to the intercellular scale.
arXiv Detail & Related papers (2020-05-27T08:23:22Z) - Optimisation of a diamond nitrogen vacancy centre magnetometer for
sensing of biological signals [44.62475518267084]
We present advances in biomagnetometry using nitrogen vacancy centres in diamond.
We show magnetic field sensitivity of approximately 100 pT/$sqrtHz$ in the DC/low frequency range using a setup designed for biological measurements.
arXiv Detail & Related papers (2020-04-05T18:44:34Z)
This list is automatically generated from the titles and abstracts of the papers in this site.
This site does not guarantee the quality of this site (including all information) and is not responsible for any consequences.