MobiVital: Self-supervised Time-series Quality Estimation for Contactless Respiration Monitoring Using UWB Radar
- URL: http://arxiv.org/abs/2503.11064v1
- Date: Fri, 14 Mar 2025 04:14:27 GMT
- Title: MobiVital: Self-supervised Time-series Quality Estimation for Contactless Respiration Monitoring Using UWB Radar
- Authors: Ziqi Wang, Derek Hua, Wenjun Jiang, Tianwei Xing, Xun Chen, Mani Srivastava,
- Abstract summary: We present a novel approach, MobiVital, that improves the quality of respiration waveforms obtained from ultra-wideband (UWB) radar data.<n> MobiVital combines a self-supervised autoregressive model for breathing waveform extraction with a biology-informed algorithm to detect and correct waveform inversions.<n>Our results show that the respiration waveforms produced by our system exhibit a 7-34% increase in fidelity to the ground truth compared to the baselines.
- Score: 10.090037080306896
- License: http://creativecommons.org/licenses/by/4.0/
- Abstract: Respiration waveforms are increasingly recognized as important biomarkers, offering insights beyond simple respiration rates, such as detecting breathing irregularities for disease diagnosis or monitoring breath patterns to guide rehabilitation training. Previous works in wireless respiration monitoring have primarily focused on estimating respiration rate, where the breath waveforms are often generated as a by-product. As a result, issues such as waveform deformation and inversion have largely been overlooked, reducing the signal's utility for applications requiring breathing waveforms. To address this problem, we present a novel approach, MobiVital, that improves the quality of respiration waveforms obtained from ultra-wideband (UWB) radar data. MobiVital combines a self-supervised autoregressive model for breathing waveform extraction with a biology-informed algorithm to detect and correct waveform inversions. To encourage reproducible research efforts for developing wireless vital signal monitoring systems, we also release a 12-person, 24-hour UWB radar vital signal dataset, with time-synchronized ground truth obtained from wearable sensors. Our results show that the respiration waveforms produced by our system exhibit a 7-34% increase in fidelity to the ground truth compared to the baselines and can benefit downstream tasks such as respiration rate estimation.
Related papers
- EchoWorld: Learning Motion-Aware World Models for Echocardiography Probe Guidance [79.66329903007869]
We present EchoWorld, a motion-aware world modeling framework for probe guidance.
It encodes anatomical knowledge and motion-induced visual dynamics.
It is trained on more than one million ultrasound images from over 200 routine scans.
arXiv Detail & Related papers (2025-04-17T16:19:05Z) - Ultrasound Lung Aeration Map via Physics-Aware Neural Operators [78.6077820217471]
Lung ultrasound is a growing modality in clinics for diagnosing acute and chronic lung diseases.<n>It is complicated by complex reverberations from the pleural interface caused by the inability of ultrasound to penetrate air.<n>We propose LUNA, an AI model that directly reconstructs lung aeration maps from RF data.
arXiv Detail & Related papers (2025-01-02T09:24:34Z) - Machine Learning-based Estimation of Respiratory Fluctuations in a Healthy Adult Population using BOLD fMRI and Head Motion Parameters [39.96015789655091]
In many fMRI studies, respiratory signals are often missing or of poor quality.
It could be highly beneficial to have a tool to extract respiratory variation (RV) waveforms directly from fMRI data without the need for peripheral recording devices.
This study proposes a CNN model for reconstruction of RV waveforms using head motion parameters and BOLD signals.
arXiv Detail & Related papers (2024-04-30T21:53:11Z) - Using BOLD-fMRI to Compute the Respiration Volume per Time (RTV) and
Respiration Variation (RV) with Convolutional Neural Networks (CNN) in the
Human Connectome Development Cohort [55.41644538483948]
This study proposes a one-dimensional CNN model for reconstruction of two respiratory measures, RV and RVT.
Results show that a CNN can capture informative features from resting BOLD signals and reconstruct realistic RV and RVT timeseries.
arXiv Detail & Related papers (2023-07-03T18:06:36Z) - Noncontact Respiratory Anomaly Detection Using Infrared Light-Wave Sensing [0.1759252234439348]
Abnormal breathing can indicate fatal health issues leading to further diagnosis and treatment.
This study simulated normal and different types of abnormal respiration using a robot that mimics human breathing patterns.
Time-series respiration data were collected using infrared light-wave sensing technology.
arXiv Detail & Related papers (2023-01-09T23:19:40Z) - Rapid Extraction of Respiratory Waveforms from Photoplethysmography: A
Deep Encoder Approach [24.594587557319837]
Much of the information of breathing is contained within the photoplethysmography signal, through changes in blood flow, heart rate and stroke volume.
We aim to leverage this fact, by employing a novel deep learning framework which is a based on a repurposed convolutional autoencoder.
We show that the model is capable of producing respiratory waveforms that approach the gold standard, while in turn producing state of the art respiratory rate estimates.
arXiv Detail & Related papers (2022-12-22T13:07:13Z) - REGAS: REspiratory-GAted Synthesis of Views for Multi-Phase CBCT
Reconstruction from a single 3D CBCT Acquisition [75.64791080418162]
REGAS proposes a self-supervised method to synthesize the undersampled tomographic views and mitigate aliasing artifacts in reconstructed images.
To address the large memory cost of deep neural networks on high resolution 4D data, REGAS introduces a novel Ray Path Transformation (RPT) that allows for distributed, differentiable forward projections.
arXiv Detail & Related papers (2022-08-17T03:42:19Z) - An Apparatus for the Simulation of Breathing Disorders: Physically
Meaningful Generation of Surrogate Data [24.50116388903113]
We introduce an apparatus comprising of PVC tubes and 3D printed parts as a simple yet effective method of simulating both obstructive and restrictive respiratory waveforms in healthy subjects.
Independent control over both inspiratory and expiratory resistances allows for the simulation of obstructive breathing disorders through the whole spectrum of FEV1/FVC spirometry ratios.
waveform characteristics of breathing disorders, such as a change in inspiratory duty cycle or peak flow are also observed in the waveforms resulting from use of the artificial breathing disorder simulation apparatus.
arXiv Detail & Related papers (2021-09-14T14:00:37Z) - Project Achoo: A Practical Model and Application for COVID-19 Detection
from Recordings of Breath, Voice, and Cough [55.45063681652457]
We propose a machine learning method to quickly triage COVID-19 using recordings made on consumer devices.
The approach combines signal processing methods with fine-tuned deep learning networks and provides methods for signal denoising, cough detection and classification.
We have also developed and deployed a mobile application that uses symptoms checker together with voice, breath and cough signals to detect COVID-19 infection.
arXiv Detail & Related papers (2021-07-12T08:07:56Z) - 2-D Respiration Navigation Framework for 3-D Continuous Cardiac Magnetic
Resonance Imaging [61.701281723900216]
We propose a sampling adaption to acquire 2-D respiration information during a continuous scan.
We develop a pipeline to extract the different respiration states from the acquired signals, which are used to reconstruct data from one respiration phase.
arXiv Detail & Related papers (2020-12-26T08:29:57Z) - Collaborative Three-Tier Architecture Non-contact Respiratory Rate
Monitoring using Target Tracking and False Peaks Eliminating Algorithms [10.232449356645608]
Non-contact respiratory monitoring techniques have poor accuracy because they are sensitive to environmental influences like lighting and motion artifacts.
frequent contact between users and the cloud might cause service request delays and potentially the loss of personal data.
We proposed a non-contact respiratory rate monitoring system with a cooperative three-layer design to increase the precision of respiratory monitoring and decrease data transmission latency.
arXiv Detail & Related papers (2020-11-17T07:33:00Z) - Identification of deep breath while moving forward based on multiple
body regions and graph signal analysis [45.62293065676075]
This paper presents an unobtrusive solution that can automatically identify deep breath when a person is walking past the global depth camera.
In validation experiments, the proposed approach outperforms the comparative methods with the accuracy, precision, recall and F1 of 75.5%, 76.2%, 75.0% and 75.2%, respectively.
arXiv Detail & Related papers (2020-10-20T08:26:50Z)
This list is automatically generated from the titles and abstracts of the papers in this site.
This site does not guarantee the quality of this site (including all information) and is not responsible for any consequences.