A robust and versatile deep learning model for prediction of the arterial input function in dynamic small animal $\left[^{18}\text{F}\right]$FDG PET imaging
- URL: http://arxiv.org/abs/2507.02367v1
- Date: Thu, 03 Jul 2025 06:55:41 GMT
- Title: A robust and versatile deep learning model for prediction of the arterial input function in dynamic small animal $\left[^{18}\text{F}\right]$FDG PET imaging
- Authors: Christian Salomonsen, Luigi Tommaso Luppino, Fredrik Aspheim, Kristoffer Wickstrøm, Elisabeth Wetzer, Michael Kampffmeyer, Rodrigo Berzaghi, Rune Sundset, Robert Jenssen, Samuel Kuttner,
- Abstract summary: This work proposes a non-invasive, fully convolutional deep learning-based approach (FC-DLIF) to predict input functions directly from PET imaging.<n>FC-DLIF includes a spatial feature extractor acting on the volumetric time frames of the PET sequence, and a temporal feature extractor that predicts the arterial input function.<n>Our deep learning-based input function offers a non-invasive and reliable alternative to arterial blood sampling, proving robust and flexible to temporal shifts and different scan durations.
- Score: 14.501528921071456
- License: http://creativecommons.org/licenses/by/4.0/
- Abstract: Dynamic positron emission tomography (PET) and kinetic modeling are pivotal in advancing tracer development research in small animal studies. Accurate kinetic modeling requires precise input function estimation, traditionally achieved via arterial blood sampling. However, arterial cannulation in small animals like mice, involves intricate, time-consuming, and terminal procedures, precluding longitudinal studies. This work proposes a non-invasive, fully convolutional deep learning-based approach (FC-DLIF) to predict input functions directly from PET imaging, potentially eliminating the need for blood sampling in dynamic small-animal PET. The proposed FC-DLIF model includes a spatial feature extractor acting on the volumetric time frames of the PET sequence, extracting spatial features. These are subsequently further processed in a temporal feature extractor that predicts the arterial input function. The proposed approach is trained and evaluated using images and arterial blood curves from [$^{18}$F]FDG data using cross validation. Further, the model applicability is evaluated on imaging data and arterial blood curves collected using two additional radiotracers ([$^{18}$F]FDOPA, and [$^{68}$Ga]PSMA). The model was further evaluated on data truncated and shifted in time, to simulate shorter, and shifted, PET scans. The proposed FC-DLIF model reliably predicts the arterial input function with respect to mean squared error and correlation. Furthermore, the FC-DLIF model is able to predict the arterial input function even from truncated and shifted samples. The model fails to predict the AIF from samples collected using different radiotracers, as these are not represented in the training data. Our deep learning-based input function offers a non-invasive and reliable alternative to arterial blood sampling, proving robust and flexible to temporal shifts and different scan durations.
Related papers
- PET Image Reconstruction Using Deep Diffusion Image Prior [3.1878756384085936]
We propose an anatomical prior-guided PET image reconstruction method based on diffusion models.<n>The proposed method alternated between diffusion sampling and model fine-tuning guided by the PET sinogram.<n>Experiment results show that the proposed PET reconstruction method can generalize robustly across tracer distributions and scanner types.
arXiv Detail & Related papers (2025-07-20T18:25:29Z) - Supervised Diffusion-Model-Based PET Image Reconstruction [44.89560992517543]
Diffusion models (DMs) have been introduced as a regularizing prior for PET image reconstruction.<n>We propose a supervised DM-based algorithm for PET reconstruction.<n>Our method enforces the non-negativity of PET's Poisson likelihood model and accommodates the wide intensity range of PET images.
arXiv Detail & Related papers (2025-06-30T16:39:50Z) - Machine Learning Derived Blood Input for Dynamic PET Images of Rat Heart [0.0]
We developed a dual output model for simultaneous estimation of model corrected blood input function (MCIF) and kinetic rate constants for dynamic FDG PET images of rat heart in vivo.<n>We used semi-automated segmentation and then formulated a Long-Short-Term Memory (LSTM) cell network to train and predict MCIF in test data using a concatenation of IDIFs and myocardial inputs.<n>The model midpoint was able to achieve a 56.4% improvement over previous Mean Squared Error (MSE)
arXiv Detail & Related papers (2025-05-21T13:10:44Z) - Anatomy-constrained modelling of image-derived input functions in dynamic PET using multi-organ segmentation [0.6359529834975265]
Accurate kinetic analysis of [$18$F]FDG distribution in dynamic positron emission tomography (PET) requires anatomically constrained modelling of image-derived input functions (IDIFs)<n>This study proposes a multi-organ segmentation-based approach that integrates IDIFs from the aorta, portal vein, pulmonary artery, and ureters.
arXiv Detail & Related papers (2025-04-23T21:47:05Z) - Finetuning and Quantization of EEG-Based Foundational BioSignal Models on ECG and PPG Data for Blood Pressure Estimation [53.2981100111204]
Photoplethysmography and electrocardiography can potentially enable continuous blood pressure (BP) monitoring.<n>Yet accurate and robust machine learning (ML) models remains challenging due to variability in data quality and patient-specific factors.<n>In this work, we investigate whether a model pre-trained on one modality can effectively be exploited to improve the accuracy of a different signal type.<n>Our approach achieves near state-of-the-art accuracy for diastolic BP and surpasses by 1.5x the accuracy of prior works for systolic BP.
arXiv Detail & Related papers (2025-02-10T13:33:12Z) - Domain Adaptive Diabetic Retinopathy Grading with Model Absence and Flowing Data [45.75724873443564]
Domain shift poses a significant challenge in clinical applications, e.g., Diabetic Retinopathy grading.<n>We propose a novel approach, Generative Unadversarial ExampleS (GUES), which enables adaptation from a data-centric perspective.
arXiv Detail & Related papers (2024-12-02T07:14:25Z) - KFD-NeRF: Rethinking Dynamic NeRF with Kalman Filter [49.85369344101118]
We introduce KFD-NeRF, a novel dynamic neural radiance field integrated with an efficient and high-quality motion reconstruction framework based on Kalman filtering.
Our key idea is to model the dynamic radiance field as a dynamic system whose temporally varying states are estimated based on two sources of knowledge: observations and predictions.
Our KFD-NeRF demonstrates similar or even superior performance within comparable computational time and state-of-the-art view synthesis performance with thorough training.
arXiv Detail & Related papers (2024-07-18T05:48:24Z) - Ambient Diffusion Posterior Sampling: Solving Inverse Problems with Diffusion Models Trained on Corrupted Data [54.09959775518994]
We provide a framework for solving inverse problems with diffusion models learned from linearly corrupted data.<n>We train diffusion models for MRI with access only to subsampled multi-coil measurements at acceleration factors R= 2,4,6,8.<n>For MRI reconstruction in high acceleration regimes, we observe that A-DPS models trained on subsampled data are better suited to solving inverse problems than models trained on fully sampled data.
arXiv Detail & Related papers (2024-03-13T17:28:20Z) - Towards Precision Cardiovascular Analysis in Zebrafish: The ZACAF
Paradigm [0.9837190842240352]
We have developed a framework to quantify the cardiac function in zebrafish.
We further applied data augmentation, Transfer Learning, and Test Time Augmentation to improve the performance.
arXiv Detail & Related papers (2024-02-15T01:58:49Z) - An end-to-end deep learning pipeline to derive blood input with partial
volume corrections for automated parametric brain PET mapping [1.3243230917306228]
A key challenge in the quantitative analysis of dFDG-PET is characterizing a patient-specific blood input function.
This research introduces a novel approach employing non-invasive deep learning model-based computations from the internal carotid arteries.
We present an end-to-end pipeline incorporating a 3D U-Net based ICA-net for ICA segmentation, alongside a Recurrent Neural Network (RNN) based MCIF-net for the derivation of a model-corrected blood input function.
arXiv Detail & Related papers (2024-02-05T17:02:30Z) - Contrastive Diffusion Model with Auxiliary Guidance for Coarse-to-Fine
PET Reconstruction [62.29541106695824]
This paper presents a coarse-to-fine PET reconstruction framework that consists of a coarse prediction module (CPM) and an iterative refinement module (IRM)
By delegating most of the computational overhead to the CPM, the overall sampling speed of our method can be significantly improved.
Two additional strategies, i.e., an auxiliary guidance strategy and a contrastive diffusion strategy, are proposed and integrated into the reconstruction process.
arXiv Detail & Related papers (2023-08-20T04:10:36Z) - StRegA: Unsupervised Anomaly Detection in Brain MRIs using a Compact
Context-encoding Variational Autoencoder [48.2010192865749]
Unsupervised anomaly detection (UAD) can learn a data distribution from an unlabelled dataset of healthy subjects and then be applied to detect out of distribution samples.
This research proposes a compact version of the "context-encoding" VAE (ceVAE) model, combined with pre and post-processing steps, creating a UAD pipeline (StRegA)
The proposed pipeline achieved a Dice score of 0.642$pm$0.101 while detecting tumours in T2w images of the BraTS dataset and 0.859$pm$0.112 while detecting artificially induced anomalies.
arXiv Detail & Related papers (2022-01-31T14:27:35Z) - A Deep Learning Approach to Predicting Collateral Flow in Stroke
Patients Using Radiomic Features from Perfusion Images [58.17507437526425]
Collateral circulation results from specialized anastomotic channels which provide oxygenated blood to regions with compromised blood flow.
The actual grading is mostly done through manual inspection of the acquired images.
We present a deep learning approach to predicting collateral flow grading in stroke patients based on radiomic features extracted from MR perfusion data.
arXiv Detail & Related papers (2021-10-24T18:58:40Z) - Direct Reconstruction of Linear Parametric Images from Dynamic PET Using
Nonlocal Deep Image Prior [13.747210115485487]
Direct reconstruction methods have been developed to estimate parametric images directly from the measured PET sinograms.
Due to limited counts received, signal-to-noise-ratio (SNR) and resolution of parametric images produced by direct reconstruction frameworks are still limited.
Recently supervised deep learning methods have been successfully applied to medical imaging denoising/reconstruction when large number of high-quality training labels are available.
arXiv Detail & Related papers (2021-06-18T21:30:22Z)
This list is automatically generated from the titles and abstracts of the papers in this site.
This site does not guarantee the quality of this site (including all information) and is not responsible for any consequences.