Inferring Optical Tissue Properties from Photoplethysmography using Hybrid Amortized Inference
- URL: http://arxiv.org/abs/2510.02073v1
- Date: Thu, 02 Oct 2025 14:36:02 GMT
- Title: Inferring Optical Tissue Properties from Photoplethysmography using Hybrid Amortized Inference
- Authors: Jens Behrmann, Maria R. Cervera, Antoine Wehenkel, Andrew C. Miller, Albert Cerussi, Pranay Jain, Vivek Venugopal, Shijie Yan, Guillermo Sapiro, Luca Pegolotti, Jörn-Henrik Jacobsen,
- Abstract summary: We introduce PPGen, a biophysical model that relates PPG signals to interpretable physiological and optical parameters.<n>We show that HAI can accurately infer physiological parameters under diverse noise and sensor conditions.
- Score: 9.6326158044961
- License: http://creativecommons.org/licenses/by/4.0/
- Abstract: Smart wearables enable continuous tracking of established biomarkers such as heart rate, heart rate variability, and blood oxygen saturation via photoplethysmography (PPG). Beyond these metrics, PPG waveforms contain richer physiological information, as recent deep learning (DL) studies demonstrate. However, DL models often rely on features with unclear physiological meaning, creating a tension between predictive power, clinical interpretability, and sensor design. We address this gap by introducing PPGen, a biophysical model that relates PPG signals to interpretable physiological and optical parameters. Building on PPGen, we propose hybrid amortized inference (HAI), enabling fast, robust, and scalable estimation of relevant physiological parameters from PPG signals while correcting for model misspecification. In extensive in-silico experiments, we show that HAI can accurately infer physiological parameters under diverse noise and sensor conditions. Our results illustrate a path toward PPG models that retain the fidelity needed for DL-based features while supporting clinical interpretation and informed hardware design.
Related papers
- EvoMorph: Counterfactual Explanations for Continuous Time-Series Extrinsic Regression Applied to Photoplethysmography [4.11690617621503]
Time-series regression models increasingly leverage photoplethysmography signals to estimate clinically relevant outcomes.<n>For clinical reasoning and trust, single point estimates alone are insufficient.<n>We introduce EvoMorph, a framework for generating physiologically plausible and diverse CFE for TSER applications.
arXiv Detail & Related papers (2026-01-15T12:58:59Z) - PMB-NN: Physiology-Centred Hybrid AI for Personalized Hemodynamic Monitoring from Photoplethysmography [2.578526056248276]
Continuous monitoring of blood pressure (BP) and hemodynamic parameters are critical for early vascular dysfunction detection.<n>Our previously proposed physiology-centered AI method-Physiological Model-Based Network (PMB-NN)-in blood pressure estimation unifies deep learning with a 2-element Windkessel based model parameterized by R and C acting as physics constraints.
arXiv Detail & Related papers (2025-12-11T15:32:50Z) - Fast Voxel-Wise Kinetic Modeling in Dynamic PET using a Physics-Informed CycleGAN [55.27156760515792]
We adopt a physics-informed CycleGAN showing promise in DCE-MRI quantification to dynamic PET quantification.<n>Our experiments demonstrate sound AIF predictions and parameter maps closely resembling the reference.
arXiv Detail & Related papers (2025-10-27T09:17:02Z) - PHASE-Net: Physics-Grounded Harmonic Attention System for Efficient Remote Photoplethysmography Measurement [63.007237197267834]
Existing deep learning methods are mostly physiological monitoring and lack theoretical robustness.<n>We propose a physics-informed r paradigm derived from the Navier-Stokes equations of hemodynamics, showing that the pulse signal follows a second-order system.<n>This provides a theoretical justification for using a Temporal Conal Network (TCN)<n>Phase-Net achieves state-of-the-art performance with strong efficiency, offering a theoretically grounded and deployment-ready r solution.
arXiv Detail & Related papers (2025-09-29T14:36:45Z) - PhysLLM: Harnessing Large Language Models for Cross-Modal Remote Physiological Sensing [49.243031514520794]
Large Language Models (LLMs) excel at capturing long-range signals due to their text-centric design.<n>PhysLLM achieves state-the-art accuracy and robustness, demonstrating superior generalization across lighting variations and motion scenarios.
arXiv Detail & Related papers (2025-05-06T15:18:38Z) - Reliable Physiological Monitoring on the Wrist Using Generative Deep Learning to Address Poor Skin-Sensor Contact [14.10775902843149]
Photoplethysmography is a widely adopted, non-invasive technique for monitoring cardiovascular health and physiological parameters in both consumer and clinical settings.<n>While motion artifacts in dynamic environments have been extensively studied, suboptimal skin-sensor contact in sedentary conditions can distort waveform morphology, leading to the loss or misalignment of key features and compromising sensing accuracy.<n>In this work, we propose CP-, a novel framework that transforms Contact Pressure-distorted PPG signals into high-fidelity waveforms with ideal morphology.
arXiv Detail & Related papers (2025-04-03T16:22:15Z) - Finetuning and Quantization of EEG-Based Foundational BioSignal Models on ECG and PPG Data for Blood Pressure Estimation [53.2981100111204]
Photoplethysmography and electrocardiography can potentially enable continuous blood pressure (BP) monitoring.<n>Yet accurate and robust machine learning (ML) models remains challenging due to variability in data quality and patient-specific factors.<n>In this work, we investigate whether a model pre-trained on one modality can effectively be exploited to improve the accuracy of a different signal type.<n>Our approach achieves near state-of-the-art accuracy for diastolic BP and surpasses by 1.5x the accuracy of prior works for systolic BP.
arXiv Detail & Related papers (2025-02-10T13:33:12Z) - Personalised and Adjustable Interval Type-2 Fuzzy-Based PPG Quality
Assessment for the Edge [0.1433758865948252]
The presented system has the potential to enable ultra-low complexity and real-time PPG quality assessment.
The proposed system obtained up to 93.72% for average accuracy during validation.
arXiv Detail & Related papers (2023-09-23T19:35:00Z) - Amplitude-Independent Machine Learning for PPG through Visibility Graphs
and Transfer Learning [16.79885220470521]
Photoplethysmography (Photoplethysmography) refers to the measurement of variations in blood volume using light.
Photoplethysmography signals provide insight into the body's circulatory system.
Photoplethysmography signals can be employed to extract various bio-features, such as heart rate and vascular ageing.
arXiv Detail & Related papers (2023-05-23T13:41:52Z) - Video-based Remote Physiological Measurement via Cross-verified Feature
Disentangling [121.50704279659253]
We propose a cross-verified feature disentangling strategy to disentangle the physiological features with non-physiological representations.
We then use the distilled physiological features for robust multi-task physiological measurements.
The disentangled features are finally used for the joint prediction of multiple physiological signals like average HR values and r signals.
arXiv Detail & Related papers (2020-07-16T09:39:17Z) - Learning Dynamic and Personalized Comorbidity Networks from Event Data
using Deep Diffusion Processes [102.02672176520382]
Comorbid diseases co-occur and progress via complex temporal patterns that vary among individuals.
In electronic health records we can observe the different diseases a patient has, but can only infer the temporal relationship between each co-morbid condition.
We develop deep diffusion processes to model "dynamic comorbidity networks"
arXiv Detail & Related papers (2020-01-08T15:47:08Z)
This list is automatically generated from the titles and abstracts of the papers in this site.
This site does not guarantee the quality of this site (including all information) and is not responsible for any consequences.