Bab_Sak Robotic Intubation System (BRIS): A Learning-Enabled Control Framework for Safe Fiberoptic Endotracheal Intubation
- URL: http://arxiv.org/abs/2512.21983v1
- Date: Fri, 26 Dec 2025 11:05:45 GMT
- Title: Bab_Sak Robotic Intubation System (BRIS): A Learning-Enabled Control Framework for Safe Fiberoptic Endotracheal Intubation
- Abstract summary: The Robotic Intubation System (BRIS) is a compact, human-in-the-loop platform designed to assist fiberoptic-guided intubation.<n>BRIS integrates a four-way steerable bronchoscope, an independent endotracheal tube mechanism, and a camera-augmented mouthpiece.<n>Monocular endoscopic depth estimation is used to classify airway regions and provide interpretable, anatomy-aware guidance.
- Score: 0.631288468490242
- License: http://creativecommons.org/licenses/by-nc-nd/4.0/
- Abstract: Endotracheal intubation is a critical yet technically demanding procedure, with failure or improper tube placement leading to severe complications. Existing robotic and teleoperated intubation systems primarily focus on airway navigation and do not provide integrated control of endotracheal tube advancement or objective verification of tube depth relative to the carina. This paper presents the Robotic Intubation System (BRIS), a compact, human-in-the-loop platform designed to assist fiberoptic-guided intubation while enabling real-time, objective depth awareness. BRIS integrates a four-way steerable fiberoptic bronchoscope, an independent endotracheal tube advancement mechanism, and a camera-augmented mouthpiece compatible with standard clinical workflows. A learning-enabled closed-loop control framework leverages real-time shape sensing to map joystick inputs to distal bronchoscope tip motion in Cartesian space, providing stable and intuitive teleoperation under tendon nonlinearities and airway contact. Monocular endoscopic depth estimation is used to classify airway regions and provide interpretable, anatomy-aware guidance for safe tube positioning relative to the carina. The system is validated on high-fidelity airway mannequins under standard and difficult airway configurations, demonstrating reliable navigation and controlled tube placement. These results highlight BRIS as a step toward safer, more consistent, and clinically compatible robotic airway management.
Related papers
- A Model-Based Decoupling Strategy for Proprioception and Contact Sensing in an Architected Soft Manipulator [49.225033144914214]
We present a model-based strategy that decouples proprioceptive and contact signals from fluidic pressure sensors embedded in a soft architected segment.<n>On a single ITH segment, this approach achieves proprioceptive shape estimation with a relative bending error of 0.11 +/- 0.02 and a contact detection rate of 97% across 178 trials.
arXiv Detail & Related papers (2026-07-17T03:03:19Z) - A Compact Top-Loading Robot for Endovascular Interventions: Design, Control and Evaluation [10.95060747006468]
Robot-assisted endovascular intervention can potentially reduce radiation exposure, improve surgeon ergonomics, enable telesurgery, and enhance procedural precision.<n>Existing systems often suffer from limited procedural coverage because constrained patient-side setups, restricted flexibility, and complex instrument exchange hinder clinical workflow integration.<n>This work presents a compact robotic system for endovascular interventions that enables continuous translational and rotational manipulation of standard endovascular instruments.
arXiv Detail & Related papers (2026-07-13T16:35:14Z) - Modeling and Control of a Pneumatic Soft Robotic Catheter Using Neural Koopman Operators [3.2642164905437503]
We propose a neural network-enhanced Koopman operator framework for advancing soft robotic catheter systems.<n>Motivated by the need to minimize radiation exposure during X-ray fluoroscopy in cardiac ablation, we investigate open-loop control strategies.<n>Our approach achieves average errors of 2.1 +- 0.4 mm in position and 4.9 +- 0.6 degrees in orientation.
arXiv Detail & Related papers (2026-03-04T14:36:22Z) - Moving Beyond Compliance in Soft-Robotic Catheters Through Modularity for Precision Therapies [0.0]
Soft robotic instruments could navigate delicate, tortuous anatomy more safely than rigid tools.<n>Few sensing and therapeutic modules are compact, robust, and adaptable enough to measure, and respond to, subtle physiological cues during intraluminal procedures.<n>We present a 1.47 mm diameter modular soft robotic catheter that integrates sensing, actuation, and therapy while retaining the compliance needed for safe endoluminal navigation.
arXiv Detail & Related papers (2026-01-21T10:11:59Z) - Reinforcement Learning for Follow-the-Leader Robotic Endoscopic Navigation via Synthetic Data [21.611096590329343]
We present a follow-the-leader endoscopic robot based on a flexible continuum structure designed to minimize contact between the endoscope body and intestinal walls.<n>We propose a vision-based deep reinforcement learning framework guided by monocular depth estimation.
arXiv Detail & Related papers (2026-01-06T08:15:53Z) - Towards Autonomous Navigation in Endovascular Interventions [0.7100795934780609]
This thesis presents an integrated AI-driven framework for autonomous guidewire navigation in complex vascular environments.<n>A high-fidelity, real-time simulation platform, CathSim, is introduced for reinforcement learning based catheter navigation.<n>The Expert Navigation Network is developed, a policy that fuses visual, kinematic, and force feedback for autonomous tool control.
arXiv Detail & Related papers (2025-12-19T21:38:52Z) - PANS: Probabilistic Airway Navigation System for Real-time Robust Bronchoscope Localization [4.755280006199144]
We propose a novel Probabilistic Airway Navigation System (PANS) for bronchoscope localization.
Our PANS incorporates diverse visual representations by leveraging two key modules, including the Depth-based Motion Inference (DMI) and the Bronchial Semantic Analysis (BSA)
Under this probabilistic formulation, our PANS is capable of achieving the 6-DOF bronchoscope localization with superior accuracy and robustness.
arXiv Detail & Related papers (2024-07-08T02:13:41Z) - CathFlow: Self-Supervised Segmentation of Catheters in Interventional Ultrasound Using Optical Flow and Transformers [66.15847237150909]
We introduce a self-supervised deep learning architecture to segment catheters in longitudinal ultrasound images.
The network architecture builds upon AiAReSeg, a segmentation transformer built with the Attention in Attention mechanism.
We validated our model on a test dataset, consisting of unseen synthetic data and images collected from silicon aorta phantoms.
arXiv Detail & Related papers (2024-03-21T15:13:36Z) - Robot-Assisted Deep Venous Thrombosis Ultrasound Examination using
Virtual Fixture [45.97156332608481]
Deep Venous Thrombosis (DVT) is a common vascular disease with blood clots inside deep veins, which may block blood flow or even cause a life-threatening pulmonary embolism.
A typical exam for DVT using ultrasound (US) imaging is by pressing the target vein until its lumens is fully compressed.
We present a robotic US system with a novel hybrid force motion control scheme ensuring position and force tracking accuracy, and soft landing of the probe onto the target surface.
arXiv Detail & Related papers (2024-01-04T21:02:39Z) - AiAReSeg: Catheter Detection and Segmentation in Interventional
Ultrasound using Transformers [75.20925220246689]
endovascular surgeries are performed using the golden standard of Fluoroscopy, which uses ionising radiation to visualise catheters and vasculature.
This work proposes a solution using an adaptation of a state-of-the-art machine learning transformer architecture to detect and segment catheters in axial interventional Ultrasound image sequences.
arXiv Detail & Related papers (2023-09-25T19:34:12Z) - Collaborative Robotic Biopsy with Trajectory Guidance and Needle Tip
Force Feedback [49.32653090178743]
We present a collaborative robotic biopsy system that combines trajectory guidance with kinesthetic feedback to assist the physician in needle placement.
A needle design that senses forces at the needle tip based on optical coherence tomography and machine learning for real-time data processing.
We demonstrate that even smaller, deep target structures can be accurately sampled by performing post-mortem in situ biopsies of the pancreas.
arXiv Detail & Related papers (2023-06-12T14:07:53Z) - Robotic Navigation Autonomy for Subretinal Injection via Intelligent
Real-Time Virtual iOCT Volume Slicing [88.99939660183881]
We propose a framework for autonomous robotic navigation for subretinal injection.
Our method consists of an instrument pose estimation method, an online registration between the robotic and the i OCT system, and trajectory planning tailored for navigation to an injection target.
Our experiments on ex-vivo porcine eyes demonstrate the precision and repeatability of the method.
arXiv Detail & Related papers (2023-01-17T21:41:21Z)
This list is automatically generated from the titles and abstracts of the papers in this site.
This site does not guarantee the quality of this site (including all information) and is not responsible for any consequences.