A Compact Top-Loading Robot for Endovascular Interventions: Design, Control and Evaluation
- URL: http://arxiv.org/abs/2607.11779v1
- Date: Mon, 13 Jul 2026 16:35:14 GMT
- Title: A Compact Top-Loading Robot for Endovascular Interventions: Design, Control and Evaluation
- Abstract summary: Robot-assisted endovascular intervention can potentially reduce radiation exposure, improve surgeon ergonomics, enable telesurgery, and enhance procedural precision.<n>Existing systems often suffer from limited procedural coverage because constrained patient-side setups, restricted flexibility, and complex instrument exchange hinder clinical workflow integration.<n>This work presents a compact robotic system for endovascular interventions that enables continuous translational and rotational manipulation of standard endovascular instruments.
- Score: 10.95060747006468
- License: http://arxiv.org/licenses/nonexclusive-distrib/1.0/
- Abstract: Robot-assisted endovascular intervention can potentially reduce radiation exposure, improve surgeon ergonomics, enable telesurgery, support active assistance and autonomy, and enhance procedural precision. However, existing systems often suffer from limited procedural coverage because constrained patient-side setups, restricted flexibility, and complex instrument exchange hinder clinical workflow integration. This work presents a compact robotic system for endovascular interventions that enables continuous translational and rotational manipulation of standard endovascular instruments. The system consists of two alternating carts with pneumatically actuated membrane grippers integrated into rotating gripper gears. Its top-loading design allows rapid exchange of instruments such as guidewires and catheters without changing the robotic setup. A leader-follower control strategy enables continuous motion despite the finite stroke of each cart. The system was evaluated in motion-tracking experiments with guidewires and catheters and in an in vitro vascular phantom. The motion-tracking experiments showed generally smooth translational and rotational motion profiles. Across all tested guidewire and catheter experiments, the mean relative tracking errors were 3.6% for translational motion and 4.1% for rotational motion. In the vascular phantom, robot-assisted navigation reached the target in most trials, demonstrating the feasibility of the proposed manipulation concept under in vitro conditions. The presented robotic system demonstrates technical feasibility for continuous manipulation of standard endovascular instruments in bench-top and in vitro experiments. The compact top-loading design may ease instrument exchange and clinical workflow integration. Future work will focus on improving gripping performance, actuation speed, force feedback, and evaluation in more clinically realistic settings.
Related papers
- Modular Robotic Catheters for Endovascular Aneurysm Repair [55.52876285801259]
endovascular aneurysm repair require surgeons to navigate catheters and guidewires into various branches of the abdominal aorta.<n>Previous clinical studies suggest that surgeons continue to struggle with vessel access using standard commercial instruments.<n>We present two contributions to solving this problem: 1) A bespoke 2-segment steerable catheter, consisting of 4 degrees of freedom to enhance dexterity.
arXiv Detail & Related papers (2026-07-28T14:53:03Z) - Eversion-based robots can enable safe access,steering and endoscopic imaging within the spinal subarachnoid space [7.4000506819669845]
We present a 2 mm diameter eversion-growing robotic platform that enables friction minimised extension and steering within the human spinal subarachnoid space.<n>The robot integrates a miniature endoscope for real time intrathecal visualisation and advances by pressure driven tip eversion.<n>In an intact human cadaver, the system achieved 150 mm of controlled intrathecal extension with concurrent fluoroscopic and endoscopic visualisation.
arXiv Detail & Related papers (2026-07-21T16:46:00Z) - The Quadruped Soft Tail: Compliant Grasping and Swabbing for Contamination Surveys in Harsh Environments [0.5233775397457061]
We have developed a lightweight, soft, and compliant tendon-actuated robotic tail mounted on a quadruped robot.<n>The tail features a hollow, flexible backbone and a tendon-actuated soft gripper that enables the robot to pick up samples and swab contaminated surfaces.<n>The proposed system combines the agility of legged locomotion with the compliance of soft robotic manipulation.
arXiv Detail & Related papers (2026-06-29T20:41:44Z) - An Experimental Modular Instrument With a Haptic Feedback Framework for Robotic Surgery Training [1.6206092886889898]
The paper presents a modular experimental robotic laparoscopic instrument integrated with a real-time haptic feedback framework.<n>The proposed instrument employs a wrist-mounted force/torque (F/T) sensor to estimate tool-tissue interaction forces.<n>A haptic feedback framework is developed to extract the external contact forces, render them to the haptic device, and generate stable and perceptually meaningful feedback.
arXiv Detail & Related papers (2026-04-30T03:55:05Z) - A Rapid Instrument Exchange System for Humanoid Robots in Minimally Invasive Surgery [9.137620295313711]
This paper proposes an immersive teleoperated rapid instrument exchange system.<n>The system utilizes a low-latency mechanism based on single-axis compliant docking and environmental constraint release.
arXiv Detail & Related papers (2026-04-03T04:05:00Z) - Moving Beyond Compliance in Soft-Robotic Catheters Through Modularity for Precision Therapies [0.0]
Soft robotic instruments could navigate delicate, tortuous anatomy more safely than rigid tools.<n>Few sensing and therapeutic modules are compact, robust, and adaptable enough to measure, and respond to, subtle physiological cues during intraluminal procedures.<n>We present a 1.47 mm diameter modular soft robotic catheter that integrates sensing, actuation, and therapy while retaining the compliance needed for safe endoluminal navigation.
arXiv Detail & Related papers (2026-01-21T10:11:59Z) - CHIP: Adaptive Compliance for Humanoid Control through Hindsight Perturbation [70.5382178207975]
hIsight Perturbation (CHIP) is a plug-and-play module that enables controllable end-effector stiffness.<n>CHIP is easy to implement and requires neither data augmentation nor additional reward tuning.<n>We show that a generalist motion-tracking controller trained with CHIP can perform a diverse set of forceful manipulation tasks.
arXiv Detail & Related papers (2025-12-16T18:56:04Z) - DINO-CVA: A Multimodal Goal-Conditioned Vision-to-Action Model for Autonomous Catheter Navigation [0.33727511459109777]
This work moves towards autonomous catheter navigation by introducing DINO-CVA, a multimodal goal-conditioned behavior cloning framework.<n>The proposed model fuses visual observations and joystick kinematics into a joint embedding space, enabling policies that are both vision-aware and kinematic-aware.<n>Results show that DINO-CVA achieves high accuracy in predicting actions, matching the performance of a kinematics-only baseline.
arXiv Detail & Related papers (2025-10-19T22:59:32Z) - AiAReSeg: Catheter Detection and Segmentation in Interventional
Ultrasound using Transformers [75.20925220246689]
endovascular surgeries are performed using the golden standard of Fluoroscopy, which uses ionising radiation to visualise catheters and vasculature.
This work proposes a solution using an adaptation of a state-of-the-art machine learning transformer architecture to detect and segment catheters in axial interventional Ultrasound image sequences.
arXiv Detail & Related papers (2023-09-25T19:34:12Z) - Collaborative Robotic Biopsy with Trajectory Guidance and Needle Tip
Force Feedback [49.32653090178743]
We present a collaborative robotic biopsy system that combines trajectory guidance with kinesthetic feedback to assist the physician in needle placement.
A needle design that senses forces at the needle tip based on optical coherence tomography and machine learning for real-time data processing.
We demonstrate that even smaller, deep target structures can be accurately sampled by performing post-mortem in situ biopsies of the pancreas.
arXiv Detail & Related papers (2023-06-12T14:07:53Z) - Neural LerPlane Representations for Fast 4D Reconstruction of Deformable
Tissues [52.886545681833596]
LerPlane is a novel method for fast and accurate reconstruction of surgical scenes under a single-viewpoint setting.
LerPlane treats surgical procedures as 4D volumes and factorizes them into explicit 2D planes of static and dynamic fields.
LerPlane shares static fields, significantly reducing the workload of dynamic tissue modeling.
arXiv Detail & Related papers (2023-05-31T14:38:35Z) - Robotic Navigation Autonomy for Subretinal Injection via Intelligent
Real-Time Virtual iOCT Volume Slicing [88.99939660183881]
We propose a framework for autonomous robotic navigation for subretinal injection.
Our method consists of an instrument pose estimation method, an online registration between the robotic and the i OCT system, and trajectory planning tailored for navigation to an injection target.
Our experiments on ex-vivo porcine eyes demonstrate the precision and repeatability of the method.
arXiv Detail & Related papers (2023-01-17T21:41:21Z) - Towards Autonomous Atlas-based Ultrasound Acquisitions in Presence of
Articulated Motion [48.52403516006036]
This paper proposes a vision-based approach allowing autonomous robotic US limb scanning.
To this end, an atlas MRI template of a human arm with annotated vascular structures is used to generate trajectories.
In all cases, the system can successfully acquire the planned vascular structure on volunteers' limbs.
arXiv Detail & Related papers (2022-08-10T15:39:20Z)
This list is automatically generated from the titles and abstracts of the papers in this site.
This site does not guarantee the quality of this site (including all information) and is not responsible for any consequences.