Moving Beyond Compliance in Soft-Robotic Catheters Through Modularity for Precision Therapies
- URL: http://arxiv.org/abs/2601.14837v1
- Date: Wed, 21 Jan 2026 10:11:59 GMT
- Title: Moving Beyond Compliance in Soft-Robotic Catheters Through Modularity for Precision Therapies
- Abstract summary: Soft robotic instruments could navigate delicate, tortuous anatomy more safely than rigid tools.<n>Few sensing and therapeutic modules are compact, robust, and adaptable enough to measure, and respond to, subtle physiological cues during intraluminal procedures.<n>We present a 1.47 mm diameter modular soft robotic catheter that integrates sensing, actuation, and therapy while retaining the compliance needed for safe endoluminal navigation.
- Score: 0.0
- License: http://creativecommons.org/licenses/by/4.0/
- Abstract: Soft robotic instruments could navigate delicate, tortuous anatomy more safely than rigid tools, but clinical adoption is limited by insufficient tip functionalization and real-time feedback at the tissue interface. Few sensing and therapeutic modules are compact, robust, and adaptable enough to measure, and respond to, subtle physiological cues during intraluminal procedures. We present a 1.47 mm diameter modular soft robotic catheter that integrates sensing, actuation, and therapy while retaining the compliance needed for safe endoluminal navigation. Validated across multiple in vivo settings, we emphasize its utility in endoscopic retrograde cholangiopancreatography (ERCP), a highly technical procedure and a key access route to the pancreas, an organ that is fragile, difficult to instrument, and central to diseases such as pancreatic cancer. Our architecture supports up to four independently controlled functional units, allowing customizable combinations of anchoring, manipulation, sensing, and targeted drug delivery. In a live porcine model, we demonstrate semi-autonomous deployment into the pancreatic duct and 7.5 cm of endoscopic navigation within it, a region currently inaccessible with standard catheters. A closed-loop autonomous/shared-control system that combines a learned model, magnetic actuation, onboard shape sensing, and visual marker tracking further improves cannulation accuracy. Together, these results establish a scalable platform for multifunctional soft robotic catheters and a new paradigm for complex endoluminal interventions, with potential to reduce radiation exposure, shorten training, and accelerate clinical translation of soft robotic technologies.
Related papers
- Modular Robotic Catheters for Endovascular Aneurysm Repair [55.52876285801259]
endovascular aneurysm repair require surgeons to navigate catheters and guidewires into various branches of the abdominal aorta.<n>Previous clinical studies suggest that surgeons continue to struggle with vessel access using standard commercial instruments.<n>We present two contributions to solving this problem: 1) A bespoke 2-segment steerable catheter, consisting of 4 degrees of freedom to enhance dexterity.
arXiv Detail & Related papers (2026-07-28T14:53:03Z) - Eversion-based robots can enable safe access,steering and endoscopic imaging within the spinal subarachnoid space [7.4000506819669845]
We present a 2 mm diameter eversion-growing robotic platform that enables friction minimised extension and steering within the human spinal subarachnoid space.<n>The robot integrates a miniature endoscope for real time intrathecal visualisation and advances by pressure driven tip eversion.<n>In an intact human cadaver, the system achieved 150 mm of controlled intrathecal extension with concurrent fluoroscopic and endoscopic visualisation.
arXiv Detail & Related papers (2026-07-21T16:46:00Z) - A Compact Top-Loading Robot for Endovascular Interventions: Design, Control and Evaluation [10.95060747006468]
Robot-assisted endovascular intervention can potentially reduce radiation exposure, improve surgeon ergonomics, enable telesurgery, and enhance procedural precision.<n>Existing systems often suffer from limited procedural coverage because constrained patient-side setups, restricted flexibility, and complex instrument exchange hinder clinical workflow integration.<n>This work presents a compact robotic system for endovascular interventions that enables continuous translational and rotational manipulation of standard endovascular instruments.
arXiv Detail & Related papers (2026-07-13T16:35:14Z) - CT-Enabled Patient-Specific Simulation and Contact-Aware Robotic Planning for Cochlear Implantation [41.386729124620366]
Robotic cochlear-implant insertion requires precise prediction and regulation of contact forces to minimize intracochlear trauma.<n>This paper presents a unified CT-to-simulation pipeline for contact-aware insertion planning and validation.
arXiv Detail & Related papers (2026-03-05T16:13:59Z) - Modeling and Control of a Pneumatic Soft Robotic Catheter Using Neural Koopman Operators [3.2642164905437503]
We propose a neural network-enhanced Koopman operator framework for advancing soft robotic catheter systems.<n>Motivated by the need to minimize radiation exposure during X-ray fluoroscopy in cardiac ablation, we investigate open-loop control strategies.<n>Our approach achieves average errors of 2.1 +- 0.4 mm in position and 4.9 +- 0.6 degrees in orientation.
arXiv Detail & Related papers (2026-03-04T14:36:22Z) - Robotic Tele-Operation for Upper Aerodigestive Tract Microsurgery: System Design and Validation [0.5872014229110214]
Upper aerodigestive tract (UADT) treatments frequently employ transoral laser microsurgery (TLM) for procedures such as the removal of tumors or polyps.<n>In TLM, a laser beam is used to cut target tissue, while forceps are employed to grasp, manipulate, and stabilize tissue within the UADT.<n>This paper proposes a novel robotic system for tissue manipulation in UADT procedures, based on a novel end-effector designed for forceps control.
arXiv Detail & Related papers (2026-01-10T16:50:05Z) - A Master-Follower Teleoperation System for Robotic Catheterization: Design, Characterization, and Tracking Control [1.0470286407954037]
This paper presents the design and development of a three-degree-of-freedom master-follower teleoperated system for robotic catheterization.<n>To resemble manual intervention by clinicians, the follower device features a grip-insert-release mechanism to eliminate catheter buckling and torsion during operation.<n>The system's performance is evaluated through approaching and open-loop path tracking over typical circular, infinity-like, and spiral paths.
arXiv Detail & Related papers (2024-07-18T05:06:48Z) - CathFlow: Self-Supervised Segmentation of Catheters in Interventional Ultrasound Using Optical Flow and Transformers [66.15847237150909]
We introduce a self-supervised deep learning architecture to segment catheters in longitudinal ultrasound images.
The network architecture builds upon AiAReSeg, a segmentation transformer built with the Attention in Attention mechanism.
We validated our model on a test dataset, consisting of unseen synthetic data and images collected from silicon aorta phantoms.
arXiv Detail & Related papers (2024-03-21T15:13:36Z) - AiAReSeg: Catheter Detection and Segmentation in Interventional
Ultrasound using Transformers [75.20925220246689]
endovascular surgeries are performed using the golden standard of Fluoroscopy, which uses ionising radiation to visualise catheters and vasculature.
This work proposes a solution using an adaptation of a state-of-the-art machine learning transformer architecture to detect and segment catheters in axial interventional Ultrasound image sequences.
arXiv Detail & Related papers (2023-09-25T19:34:12Z) - Collaborative Robotic Biopsy with Trajectory Guidance and Needle Tip
Force Feedback [49.32653090178743]
We present a collaborative robotic biopsy system that combines trajectory guidance with kinesthetic feedback to assist the physician in needle placement.
A needle design that senses forces at the needle tip based on optical coherence tomography and machine learning for real-time data processing.
We demonstrate that even smaller, deep target structures can be accurately sampled by performing post-mortem in situ biopsies of the pancreas.
arXiv Detail & Related papers (2023-06-12T14:07:53Z) - Robotic Navigation Autonomy for Subretinal Injection via Intelligent
Real-Time Virtual iOCT Volume Slicing [88.99939660183881]
We propose a framework for autonomous robotic navigation for subretinal injection.
Our method consists of an instrument pose estimation method, an online registration between the robotic and the i OCT system, and trajectory planning tailored for navigation to an injection target.
Our experiments on ex-vivo porcine eyes demonstrate the precision and repeatability of the method.
arXiv Detail & Related papers (2023-01-17T21:41:21Z) - Towards Autonomous Atlas-based Ultrasound Acquisitions in Presence of
Articulated Motion [48.52403516006036]
This paper proposes a vision-based approach allowing autonomous robotic US limb scanning.
To this end, an atlas MRI template of a human arm with annotated vascular structures is used to generate trajectories.
In all cases, the system can successfully acquire the planned vascular structure on volunteers' limbs.
arXiv Detail & Related papers (2022-08-10T15:39:20Z)
This list is automatically generated from the titles and abstracts of the papers in this site.