Automated Robotic Needle Puncture for Percutaneous Dilatational Tracheostomy
- URL: http://arxiv.org/abs/2602.22952v1
- Date: Thu, 26 Feb 2026 12:47:04 GMT
- Title: Automated Robotic Needle Puncture for Percutaneous Dilatational Tracheostomy
- Abstract summary: Percutaneous dilatationaleostomy (PDT) is frequently performed on patients in intensive care units.<n>Current practices of PDT puncture are all performed manually with no navigation assistance.<n>We propose a system that automates the needle insertion using a velocity-controlled robotic manipulator.
- Score: 7.122041813412971
- License: http://creativecommons.org/licenses/by/4.0/
- Abstract: Percutaneous dilatational tracheostomy (PDT) is frequently performed on patients in intensive care units for prolonged mechanical ventilation. The needle puncture, as the most critical step of PDT, could lead to adverse consequences such as major bleeding and posterior tracheal wall perforation if performed inaccurately. Current practices of PDT puncture are all performed manually with no navigation assistance, which leads to large position and angular errors (5 mm and 30 degree). To improve the accuracy and reduce the difficulty of the PDT procedure, we propose a system that automates the needle insertion using a velocity-controlled robotic manipulator. Guided using pose data from two electromagnetic sensors, one at the needle tip and the other inside the trachea, the robotic system uses an adaptive constrained controller to adapt the uncertain kinematic parameters online and avoid collisions with the patient's body and tissues near the target. Simulations were performed to validate the controller's implementation, and then four hundred PDT punctures were performed on a mannequin to evaluate the position and angular accuracy. The absolute median puncture position error was 1.7 mm (IQR: 1.9 mm) and midline deviation was 4.13 degree (IQR: 4.55 degree), measured by the sensor inside the trachea. The small deviations from the nominal puncture in a simulated experimental setup and formal guarantees of collision-free insertions suggest the feasibility of the robotic PDT puncture.
Related papers
- Control Architecture and experimental validation of a Novel Surgical Robotic Instrument [0.7078141380481605]
Minimally invasive surgery (MIS) reduces patient trauma and shortens recovery time.<n> conventional laparoscopic instruments remain constrained by limited range of movements.<n>This work presents the control architecture of a 4-DOF flexible laparoscopic instrument integrating distal bending, independent distal head rotation, shaft rotation, and a gripper.
arXiv Detail & Related papers (2026-04-07T09:00:59Z) - Bilinear Model Predictive Control Framework of the OncoReach, a Tendon-Driven Steerable Stylet for Brachytherapy [0.11726720776908518]
Steerable needles have the potential to improve interstitial brachytherapy by enabling curved trajectories that avoid sensitive anatomical structures.<n>Existing modeling and control approaches are primarily developed for custom needle designs and are not directly applicable to stylets compatible with commercially available clinical needles.<n>This paper presents a bilinear model predictive control framework for a tendon-driven steerable stylet integrated with a standard brachytherapy needle.
arXiv Detail & Related papers (2026-04-06T19:17:43Z) - CT-Enabled Patient-Specific Simulation and Contact-Aware Robotic Planning for Cochlear Implantation [41.386729124620366]
Robotic cochlear-implant insertion requires precise prediction and regulation of contact forces to minimize intracochlear trauma.<n>This paper presents a unified CT-to-simulation pipeline for contact-aware insertion planning and validation.
arXiv Detail & Related papers (2026-03-05T16:13:59Z) - Organ-Agents: Virtual Human Physiology Simulator via LLMs [66.40796430669158]
Organ-Agents is a multi-agent framework that simulates human physiology via LLM-driven agents.<n>We curated data from 7,134 sepsis patients and 7,895 controls, generating high-resolution trajectories across 9 systems and 125 variables.<n>Organ-Agents achieved high simulation accuracy on 4,509 held-out patients, with per-system MSEs 0.16 and robustness across SOFA-based severity strata.
arXiv Detail & Related papers (2025-08-20T01:58:45Z) - A Master-Follower Teleoperation System for Robotic Catheterization: Design, Characterization, and Tracking Control [1.0470286407954037]
This paper presents the design and development of a three-degree-of-freedom master-follower teleoperated system for robotic catheterization.<n>To resemble manual intervention by clinicians, the follower device features a grip-insert-release mechanism to eliminate catheter buckling and torsion during operation.<n>The system's performance is evaluated through approaching and open-loop path tracking over typical circular, infinity-like, and spiral paths.
arXiv Detail & Related papers (2024-07-18T05:06:48Z) - Robot-Assisted Deep Venous Thrombosis Ultrasound Examination using
Virtual Fixture [45.97156332608481]
Deep Venous Thrombosis (DVT) is a common vascular disease with blood clots inside deep veins, which may block blood flow or even cause a life-threatening pulmonary embolism.
A typical exam for DVT using ultrasound (US) imaging is by pressing the target vein until its lumens is fully compressed.
We present a robotic US system with a novel hybrid force motion control scheme ensuring position and force tracking accuracy, and soft landing of the probe onto the target surface.
arXiv Detail & Related papers (2024-01-04T21:02:39Z) - EyeLS: Shadow-Guided Instrument Landing System for Intraocular Target
Approaching in Robotic Eye Surgery [51.05595735405451]
Robotic ophthalmic surgery is an emerging technology to facilitate high-precision interventions such as retina penetration in subretinal injection and removal of floating tissues in retinal detachment.
Current image-based methods cannot effectively estimate the needle tip's trajectory towards both retinal and floating targets.
We propose to use the shadow positions of the target and the instrument tip to estimate their relative depth position.
Our method succeeds target approaching on a retina model, and achieves an average depth error of 0.0127 mm and 0.3473 mm for floating and retinal targets respectively in the surgical simulator.
arXiv Detail & Related papers (2023-11-15T09:11:37Z) - Medical needle tip tracking based on Optical Imaging and AI [0.0]
This paper presents an innovative technology for needle tip real-time tracking, aiming for enhanced needle insertion guidance.
Specifically, our approach revolves around the creation of scattering imaging using an optical fiber-equipped needle, and uses Convolutional Neural Network (CNN) based algorithms to enable real-time estimation of the needle tip's position and orientation.
Given the average femoral arterial radius of 4 to 5mm, the proposed system is demonstrated with a great potential for precise needle guidance in femoral artery insertion procedures.
arXiv Detail & Related papers (2023-08-28T10:30:08Z) - WarpEM: Dynamic Time Warping for Accurate Catheter Registration in
EM-guided Procedures [42.72633281833923]
This paper introduces a novel automated catheter registration method for EM-guided MIEP.
The method utilizes 3D signal temporal analysis, such as Dynamic Time Warping (DTW) algorithms, to improve registration accuracy and reliability.
The results indicate that the DTW method yields accurate and reliable registration outcomes, with a mean error of $2.22$mm.
arXiv Detail & Related papers (2023-08-07T15:07:21Z) - Automatic registration with continuous pose updates for marker-less
surgical navigation in spine surgery [52.63271687382495]
We present an approach that automatically solves the registration problem for lumbar spinal fusion surgery in a radiation-free manner.
A deep neural network was trained to segment the lumbar spine and simultaneously predict its orientation, yielding an initial pose for preoperative models.
An intuitive surgical guidance is provided thanks to the integration into an augmented reality based navigation system.
arXiv Detail & Related papers (2023-08-05T16:26:41Z) - A Novel Sample-efficient Deep Reinforcement Learning with Episodic
Policy Transfer for PID-Based Control in Cardiac Catheterization Robots [2.3939470784308914]
The model was validated for axial motion control of a robotic system designed for intravascular catheterization.
Performance comparison with conventional methods in average of 10 trials shows the agent tunes the gain better with error of 0.003 mm.
arXiv Detail & Related papers (2021-10-28T08:18:01Z) - Online Body Schema Adaptation through Cost-Sensitive Active Learning [63.84207660737483]
The work was implemented in a simulation environment, using the 7DoF arm of the iCub robot simulator.
A cost-sensitive active learning approach is used to select optimal joint configurations.
The results show cost-sensitive active learning has similar accuracy to the standard active learning approach, while reducing in about half the executed movement.
arXiv Detail & Related papers (2021-01-26T16:01:02Z) - Accurate Alignment Inspection System for Low-resolution Automotive and
Mobility LiDAR [125.41260574344933]
An accurate inspection system is proposed for estimating a LiDAR alignment error after sensor attachment on a mobility system such as a vehicle or robot.
The proposed method uses only a single target board at the fixed position to estimate the three orientations (roll, tilt, and yaw) and the horizontal position of the LiDAR attachment with sub-degree and millimeter level accuracy.
arXiv Detail & Related papers (2020-08-24T17:47:59Z)
This list is automatically generated from the titles and abstracts of the papers in this site.
This site does not guarantee the quality of this site (including all information) and is not responsible for any consequences.