Generalizable CT-Free PET Attenuation and Scatter Correction for Pediatric Patients
- URL: http://arxiv.org/abs/2604.22894v1
- Date: Fri, 24 Apr 2026 10:55:19 GMT
- Title: Generalizable CT-Free PET Attenuation and Scatter Correction for Pediatric Patients
- Abstract summary: Existing CT-free methods are commonly trained in homogeneous settings and often degrade under scanner or radiotracer shifts.<n>We propose the Generalizable PET Correction Network (GPCN), a dual-domain network for domain-robust CT-free PET attenuation and scatter correction.
- Score: 16.406616011746944
- License: http://arxiv.org/licenses/nonexclusive-distrib/1.0/
- Abstract: Computed tomography (CT)-based attenuation and scatter correction improves quantitative PET but adds radiation exposure that is particularly undesirable in pediatric imaging. Existing CT-free methods are commonly trained in homogeneous settings and often degrade under scanner or radiotracer shifts, which limits their clinical utility. We propose the Generalizable PET Correction Network (GPCN), a dual-domain network for domain-robust CT-free PET attenuation and scatter correction. GPCN combines a multi-band contextual refinement module, which models pediatric anatomical variability through wavelet-based multiscale decomposition and long-range spatial context modeling, with a frequency-aware spectral decoupling module, which performs coordinate-conditioned amplitude/phase refinement in the Fourier domain. By synergizing multi-band spatial contextual modeling with asymmetric frequency-spectrum decoupling, the network explicitly separates invariant topological structures from domain-specific noise, thereby achieving precise quantitative recovery of both anatomical organs and focal lesions. This design aims to separate anatomy-dominant structures from domain-sensitive spectral residuals and to improve robustness across heterogeneous imaging conditions. We train and evaluate the method on 1085 pediatric whole-body PET scans acquired with two scanners and five radiotracers. In both joint training and zero-shot cross-domain evaluation, GPCN outperforms representative baselines and maintains stable quantitative accuracy on unseen scanner-tracer combinations. The method is further supported by ablation, region-wise quantitative analysis, and downstream segmentation experiments. In our cohort, the CT component of the conventional protocol corresponded to an average effective dose of 10.8 mSv, indicating the potential clinical value of reliable CT-free correction for pediatric PET.
Related papers
- A Dual Path Framework with Hotspot Guided Fusion for Three Dimensional CT to PET Synthesis in Head and Neck Cancer [0.0]
18F-FDG PET/CT plays a central role in staging, treatment planning, and response assessment for head and neck cancer.<n>We present a proof of concept deep learning framework for synthesizing PET like images directly from routine CT scans.
arXiv Detail & Related papers (2026-07-23T20:33:50Z) - Improving PET/CT-Based Whole-Body Lesion Segmentation Using Prediction Uncertainty-Augmented Models [4.533732724414947]
Lesion delineation from PET/CT imaging is clinically challenging due to subtle imaging features, confounders, and inter-reader variability.<n>Existing deep learning approaches suffer from training-relatedity, inconsistent predictions, missed lesions in high tumor-burden cases, and lack uncertainty.<n>We propose an uncertainty-aware framework for whole-body PET/CT lesion segmentation.
arXiv Detail & Related papers (2026-06-08T19:49:23Z) - Multi-Contrast MRI Motion Correction via Parameter-Informed Disentanglement and Adaptive Experts [56.74856091904914]
We propose a unified framework combining parameter-informed contrast disentanglement with severity-aware adaptive correction.<n>ScanCLIP derives contrast embeddings from acquisition parameters to disentangle contrast style from anatomical content, yielding contrast-free features.<n>A Vision Transformer then estimates motion severity and routes features through a Mixture-of-Experts network, enabling targeted artifact correction.
arXiv Detail & Related papers (2026-05-29T02:48:23Z) - Distilling Photon-Counting CT into Routine Chest CT through Clinically Validated Degradation Modeling [51.330452704464925]
We train a latent diffusion model on 1,046 PCCTs and 405,379 EICTs from 145 hospitals.<n>We construct a large-scale dataset of over 17,316 publicly available EICTs enhanced to PCCT-like quality.<n>Our results suggest emerging imaging advances can be systematically distilled into routine EICT using limited high-quality scans as reference.
arXiv Detail & Related papers (2026-04-08T17:47:35Z) - PHASOR: Anatomy- and Phase-Consistent Volumetric Diffusion for CT Virtual Contrast Enhancement [60.81732730684265]
This paper introduces PHASOR, a volumetric diffusion framework for high-fidelity virtual contrast enhancement (VCE)<n>By treating CT volumes as coherent sequences, we leverage a video diffusion model to enhance structural coherence and volumetric accuracy.<n>To ensure anatomy-phase consistent synthesis, we introduce two complementary modules. First, anatomy-routed mixture-of-experts (AR-MoE) anchors distinct enhancement patterns to anatomical semantics, with organ-specific memory to capture salient details.<n>Second, intensity-phase aware representation alignment (IP-REPA) highlights intricate contrast signals while mitigating the impact of imperfect spatial alignment.
arXiv Detail & Related papers (2026-04-01T15:57:18Z) - CT-Conditioned Diffusion Prior with Physics-Constrained Sampling for PET Super-Resolution [25.790321547743066]
We formulate PET super-resolution as posterior inference under heterogeneous system configurations.<n>We propose a CT-conditioned diffusion framework with physics-constrained sampling.<n>Under both standard and OOD settings, the proposed method consistently improves experimental metrics and lesion-level clinical relevance indicators.
arXiv Detail & Related papers (2026-03-14T11:28:23Z) - CT-Less Attenuation Correction Using Multiview Ensemble Conditional Diffusion Model on High-Resolution Uncorrected PET Images [31.66812884304363]
Attenuation refers to the diminution of photon detected as they traverse biological tissues before reaching detectors.<n>New advances in neural network architectures present an alternative approach via synthetic CT image synthesis.<n>Results from a study of 159 head scans acquired with the Siemens Biograph Vision PET/CT scanner demonstrate both qualitative and quantitative improvements in pseudo-CT generation.
arXiv Detail & Related papers (2025-10-28T01:18:35Z) - EqDiff-CT: Equivariant Conditional Diffusion model for CT Image Synthesis from CBCT [43.92108185590778]
Cone-beam computed tomography (CBCT) is widely used for imageguided radiotherapy (IGRT)<n>We propose a novel diffusion-based conditional generative model, coined EqDiff-CT, to synthesize high-quality CT images from CBCT.
arXiv Detail & Related papers (2025-09-26T05:51:59Z) - JSover: Joint Spectrum Estimation and Multi-Material Decomposition from Single-Energy CT Projections [45.14515691206885]
Multi-material decomposition (MMD) enables quantitative reconstruction of tissue compositions in the human body.<n>Traditional MMD typically requires spectral CT scanners and pre-measured X-ray energy spectra, significantly limiting clinical applicability.<n>This paper proposes JSover, a fundamentally reformulated one-step SEMMD framework that jointly reconstructs multi-material compositions and estimates the energy spectrum directly from SECT projections.
arXiv Detail & Related papers (2025-05-12T23:32:21Z) - Two-stage deep learning framework for the restoration of incomplete-ring PET images [0.6478690173421426]
We present a two-stage deep-learning framework that restores high-quality images from data with about 50% missing coincidences.<n>We also achieve higher inference speed, thus providing an effective solution for incomplete-ring PET imaging.
arXiv Detail & Related papers (2025-04-01T14:05:32Z) - Whole-Body Image-to-Image Translation for a Virtual Scanner in a Healthcare Digital Twin [0.8714814768600079]
We propose a framework that segments whole-body CT images into four regions-head, trunk, arms, and legs-and uses district-specific Generative Adversarial Networks (GANs) for tailored CT-to-PET translation.<n>This methodology supports healthcare Digital Twins by enabling accurate virtual PET scans from CT data, creating virtual imaging representations to monitor, predict, and optimize health outcomes.
arXiv Detail & Related papers (2025-03-18T20:19:28Z) - Contrastive Diffusion Model with Auxiliary Guidance for Coarse-to-Fine
PET Reconstruction [62.29541106695824]
This paper presents a coarse-to-fine PET reconstruction framework that consists of a coarse prediction module (CPM) and an iterative refinement module (IRM)
By delegating most of the computational overhead to the CPM, the overall sampling speed of our method can be significantly improved.
Two additional strategies, i.e., an auxiliary guidance strategy and a contrastive diffusion strategy, are proposed and integrated into the reconstruction process.
arXiv Detail & Related papers (2023-08-20T04:10:36Z) - Symmetry-Enhanced Attention Network for Acute Ischemic Infarct
Segmentation with Non-Contrast CT Images [50.55978219682419]
We propose a symmetry enhanced attention network (SEAN) for acute ischemic infarct segmentation.
Our proposed network automatically transforms an input CT image into the standard space where the brain tissue is bilaterally symmetric.
The proposed SEAN outperforms some symmetry-based state-of-the-art methods in terms of both dice coefficient and infarct localization.
arXiv Detail & Related papers (2021-10-11T07:13:26Z)
This list is automatically generated from the titles and abstracts of the papers in this site.
This site does not guarantee the quality of this site (including all information) and is not responsible for any consequences.