Attractor-Vascular Coupling Theory: Formal Grounding and Empirical Validation for AAMI-Standard Cuffless Blood Pressure Estimation from Smartphone Photoplethysmography
- URL: http://arxiv.org/abs/2605.10871v2
- Date: Sun, 17 May 2026 18:50:48 GMT
- Title: Attractor-Vascular Coupling Theory: Formal Grounding and Empirical Validation for AAMI-Standard Cuffless Blood Pressure Estimation from Smartphone Photoplethysmography
- Abstract summary: It shows that cardiac attractor geometry encodes blood pressure information sufficient for AAMI-standard estimation.<n>It is operationalized using Takens delay embedding and attractor morphology extraction.
- Score: 1.1344265020822928
- License: http://creativecommons.org/licenses/by-nc-sa/4.0/
- Abstract: This work proposes Attractor-Vascular Coupling Theory (AVCT), a mathematical framework showing that cardiac attractor geometry encodes blood pressure (BP) information sufficient for AAMI-standard estimation, and validates the theory through a calibrated cuffless BP model using photoplethysmography (PPG). AVCT is grounded in Cardiac Stability Theory and operationalized using Takens delay embedding and attractor morphology extraction. Two theorems, one proposition, and one corollary formally justify the use of PPG attractor features for BP estimation and predict the feature-importance hierarchy. A LightGBM model trained on pulse transit time (PTT) and Cardiac Stability Index (CSI) attractor features under single-point calibration was evaluated using strict leave-one-subject-out cross-validation (LOSO-CV) on 46 subjects from BIDMC ICU (n = 9) and VitalDB surgical data (n = 37), comprising 29,684 windows. The model achieved systolic BP (SBP) mean absolute error (MAE) of 2.05 mmHg and diastolic BP (DBP) MAE of 1.67 mmHg, with correlations r = 0.990 and r = 0.991, satisfying the AAMI/IEEE SP10 requirement of MAE below 5 mmHg. Median per-subject MAE was 1.87/1.54 mmHg, and 70%/76% of subjects individually satisfied AAMI criteria. A PPG-only ablation using nine smartphone attractor features matched the ECG+PPG model within 0.05 mmHg, demonstrating that clinical-grade BP tracking is achievable using only a smartphone camera while surpassing prior generalized LOSO-CV results using fewer sensors. All four AVCT predictions were quantitatively confirmed, with 91.5% error reduction from uncalibrated to calibrated estimation (epsilon_cal = 0.915). Unlike post-hoc explainable AI methods, AVCT predicts features satisfying the architectural faithfulness criterion of the Explainable-AI Trustworthiness (EAT) framework and grounding BP estimation in nonlinear dynamical systems theory.
Related papers
- Single-Beat Cuffless Blood Pressure Estimation Using Ear-PPG and ECG with a Lightweight Hybrid Learning Framework [0.7015649288674913]
Continuous cuffless blood pressure (BP) monitoring is challenging due to motion artifacts, physiological variability, and the limited robustness of conventional pulse transit time (PTT) models under dynamic conditions.<n>Here, we show that discriminative BP-related information is preserved at the single-beat level and present a lightweight multi-modal wearable framework for continuous BP estimation.
arXiv Detail & Related papers (2026-07-29T16:00:39Z) - In-Hospital Stroke Prediction from PPG-Derived Hemodynamic Features [34.880478990331916]
We develop an LLM-assisted data mining pipeline to extract precise in-hospital stroke onset timestamps from unstructured clinical notes.<n>We then extract hemodynamic features from PPG and employ a ResNet-1D model to predict impending stroke across multiple early-warning horizons.<n>These results provide the first empirical evidence from real-world clinical data that PPG contains predictive signatures of stroke several hours before onset.
arXiv Detail & Related papers (2026-02-10T01:50:26Z) - PMB-NN: Physiology-Centred Hybrid AI for Personalized Hemodynamic Monitoring from Photoplethysmography [2.578526056248276]
Continuous monitoring of blood pressure (BP) and hemodynamic parameters are critical for early vascular dysfunction detection.<n>Our previously proposed physiology-centered AI method-Physiological Model-Based Network (PMB-NN)-in blood pressure estimation unifies deep learning with a 2-element Windkessel based model parameterized by R and C acting as physics constraints.
arXiv Detail & Related papers (2025-12-11T15:32:50Z) - Cuffless Blood Pressure Estimation from Six Wearable Sensor Modalities in Multi-Motion-State Scenarios [0.7871262900865523]
The proposed method achieves mean absolute errors (MAE) of 3.60 mmHg for systolic BP (SBP) and 3.01 mmHg for diastolic BP (DBP)<n>From a clinical perspective, it attains Grade A for SBP, DBP, andMAP according to the British Hypertension Society (BHS) protocol.
arXiv Detail & Related papers (2025-12-01T13:26:30Z) - A Novel Attention-Augmented Wavelet YOLO System for Real-time Brain Vessel Segmentation on Transcranial Color-coded Doppler [49.03919553747297]
We propose an AI-powered, real-time CoW auto-segmentation system capable of efficiently capturing cerebral arteries.<n>No prior studies have explored AI-driven cerebrovascular segmentation using Transcranial Color-coded Doppler (TCCD)<n>The proposed AAW-YOLO demonstrated strong performance in segmenting both ipsilateral and contralateral CoW vessels.
arXiv Detail & Related papers (2025-08-19T14:41:22Z) - HistoART: Histopathology Artifact Detection and Reporting Tool [37.31105955164019]
Whole Slide Imaging (WSI) is widely used to digitize tissue specimens for detailed, high-resolution examination.<n>WSI remains vulnerable to artifacts introduced during slide preparation and scanning.<n>We propose and compare three robust artifact detection approaches for WSIs.
arXiv Detail & Related papers (2025-06-23T17:22:19Z) - Diagnosis of Pulmonary Hypertension by Integrating Multimodal Data with a Hybrid Graph Convolutional and Transformer Network [32.50971951245164]
This study develops and validates a deep learning-based diagnostic model for pulmonary hypertension (PH)<n>It is designed to classify patients as non-PH, pre-capillary PH, or post-capillary PH.<n>It has the potential to support clinical decision-making by effectively integrating multimodal data.
arXiv Detail & Related papers (2025-03-28T01:14:17Z) - Finetuning and Quantization of EEG-Based Foundational BioSignal Models on ECG and PPG Data for Blood Pressure Estimation [46.36100528165335]
Photoplethysmography and electrocardiography can potentially enable continuous blood pressure (BP) monitoring.<n>Yet accurate and robust machine learning (ML) models remains challenging due to variability in data quality and patient-specific factors.<n>In this work, we investigate whether a model pre-trained on one modality can effectively be exploited to improve the accuracy of a different signal type.<n>Our approach achieves near state-of-the-art accuracy for diastolic BP and surpasses by 1.5x the accuracy of prior works for systolic BP.
arXiv Detail & Related papers (2025-02-10T13:33:12Z) - TransfoRhythm: A Transformer Architecture Conductive to Blood Pressure Estimation via Solo PPG Signal Capturing [5.255373360156652]
The paper introduces the TransfoRhythm framework, a Transformer-based architecture built upon the recently released physiological database, MIMIC-IV.<n>To our knowledge, this paper represents the first study to apply the MIMIC IV dataset for cuff-less BP estimation.
arXiv Detail & Related papers (2024-04-15T00:36:33Z) - Development of Automated Neural Network Prediction for Echocardiographic Left ventricular Ejection Fraction [36.58987036154144]
This paper proposes a new pipeline method based on deep neural networks and ensemble learning to quantify left ventricular ejection fraction (LVEF)
The method was developed and validated in an open-source dataset containing 10,030 echocardiograms.
This study demonstrates that an automated neural network-based calculation of LVEF is comparable to expert clinicians performing frame-by-frame manual evaluation of cardiac systolic function.
arXiv Detail & Related papers (2024-03-18T18:09:22Z) - A Finger on the Pulse of Cardiovascular Health: Estimating Blood Pressure with Smartphone Photoplethysmography-Based Pulse Waveform Analysis [2.4347312660509672]
This study introduces four innovative strategies to enhance smartphone-based photoplethysmography for blood pressure estimation (SPW-BP)
We employ often-neglected data-quality improvement techniques, such as height normalization, corrupt data removal, and boundary signal reconstruction.
Correlation and SHAP analysis identified key features for improving BP estimation.
However, Bland-Altman analysis revealed systematic biases, and MAE analysis showed that the results did not meet AAMI and BHS accuracy standards.
arXiv Detail & Related papers (2024-01-20T05:05:17Z)