Evidence-Based Text-Conditioned 3D CT Synthesis for Ovarian Cancer
- URL: http://arxiv.org/abs/2606.28980v1
- Date: Sat, 27 Jun 2026 15:30:29 GMT
- Title: Evidence-Based Text-Conditioned 3D CT Synthesis for Ovarian Cancer
- Abstract summary: Ovarian cancer is frequently diagnosed at an advanced stage, making preoperative contrast-enhanced computed tomography (CT) central to staging and surgical planning.<n>Text-conditioned 3D CT synthesis has shown promise, but existing pipelines depend on paired radiology reports and have been evaluated only on chest CT.<n>We propose OvESyn, a framework that constructs standardized Findings and Impression sections directly from CT-derived imaging descriptors and routine clinical metadata.
- Score: 9.862634656196759
- License: http://creativecommons.org/licenses/by/4.0/
- Abstract: Ovarian cancer is frequently diagnosed at an advanced stage, making preoperative contrast-enhanced computed tomography (CT) central to staging and surgical planning; yet the scarcity of annotated imaging data, compounded by privacy regulations, limits the development of generalizable computational models in this domain. Text-conditioned 3D CT synthesis has shown promise, but existing pipelines depend on paired radiology reports and have been evaluated only on chest CT. We propose OvESyn (Ovarian Evidence-based Synthesis), a framework that constructs standardized Findings and Impression sections directly from CT-derived imaging descriptors and routine clinical metadata, without any original radiology report, and uses them to condition a latent diffusion model adapted to 493 high-grade serous ovarian carcinoma patients. This is the first text-conditioned 3D CT synthesis framework adapted to an abdomino-pelvic oncologic setting. A systematic ablation over two adaptation axes, vision-language encoder alignment and generator fine-tuning, identifies generator domain adaptation as the operative mechanism for crossing the domain gap and establishing the target anatomy: without it, synthesis remains anchored to the thoracic pretraining domain, with Precision and Recall collapsing to zero and FID2.5D exceeding 140, regardless of encoder alignment. Encoder alignment instead refines intensity and fine detail. The full OvESyn attains the best distributional and intensity fidelity (FID2.5D 29.35, Precision 0.671, Wasserstein-1 0.044), while the generator-only variant maximizes coverage (Recall 0.645), reflecting a fidelity/coverage trade-off governed by encoder adaptation. Requiring only automatic segmentations and routine preoperative metadata, OvESyn supports transferability to report-scarce settings and provides a foundation for synthetic cohort generation in abdomino-pelvic oncologic imaging.
Related papers
- ViT3Flow: A Test-Time Training Transformer MeanFlow for Postoperative Radiograph Synthesis in Scoliosis [24.805863115698475]
We formulate this problem as postoperative scoliosis radiograph synthesis and construct ScoliSurg, the first paired dataset for this task.<n>We propose ViT$3$Flow, a single-NFE conditional MeanFlow framework for efficient postoperative radiograph synthesis.
arXiv Detail & Related papers (2026-09-04T12:14:33Z) - B-MIM: Biased Masked Image Modeling for Generalizable Segmentation of Fine-Grained Anatomical Structures [42.844780603412325]
Self-supervised pretraining enables transferable representations for medical imaging.<n>Most CT encoders remain biased toward coarse semantic understanding.<n>We introduce Biased Masked Image Modeling to reduce global semantic alignment.
arXiv Detail & Related papers (2026-08-25T10:20:05Z) - Metadata-Aware Adaptation of a Generative Foundation Model for Conditional CMR Synthesis [1.5538501783439032]
Synthetic image generation is a promising strategy to address data scarcity and the underrepresentation of clinically important phenotypes in medical imaging.<n>In this work, we investigate metadata-conditioned cardiac magnetic resonance (CMR) synthesis using a pretrained latent model.<n>The framework was fine-tuned and evaluated on 59,058 short-axis CMR from the UK Biobank using paired image similarity, distributional fidelity, and subgroup-level analyses.
arXiv Detail & Related papers (2026-08-25T10:03:46Z) - Disease-Centric Vision-Language Pretraining with Hybrid Visual Encoding for 3D Computed Tomography [75.7789001619107]
Vision-language pre-training holds great promise for general-purpose medical AI.<n>We propose a tailored framework featuring three key components.<n>A diagnosis-aware prompt strategy employs real clinical phrases and aggregated disease prototypes to bridge the pre-training-inference gap.
arXiv Detail & Related papers (2026-06-24T08:24:45Z) - 3D Ultrasound-Derived Pseudo-CT Synthesis Using a Transformer-Augmented Residual Network for Real-Time Operator Guidance [0.0]
Ultrasound (US) is non-ionizing and widely accessible; however, it is highly operator dependent and lacks quantitative tissue characterization.<n>This work presents a 3D ultrasound-derived pseudo-CT framework that generates CT-like anatomical reference volumes inferred from US.<n>The proposed method outperforms established baselines in structural fidelity and perceptual image quality.
arXiv Detail & Related papers (2026-05-06T12:52:59Z) - PHASOR: Anatomy- and Phase-Consistent Volumetric Diffusion for CT Virtual Contrast Enhancement [60.81732730684265]
This paper introduces PHASOR, a volumetric diffusion framework for high-fidelity virtual contrast enhancement (VCE)<n>By treating CT volumes as coherent sequences, we leverage a video diffusion model to enhance structural coherence and volumetric accuracy.<n>To ensure anatomy-phase consistent synthesis, we introduce two complementary modules. First, anatomy-routed mixture-of-experts (AR-MoE) anchors distinct enhancement patterns to anatomical semantics, with organ-specific memory to capture salient details.<n>Second, intensity-phase aware representation alignment (IP-REPA) highlights intricate contrast signals while mitigating the impact of imperfect spatial alignment.
arXiv Detail & Related papers (2026-04-01T15:57:18Z) - Beyond the Embedding Bottleneck: Adaptive Retrieval-Augmented 3D CT Report Generation [10.885951167009694]
3D CT embeddings encode discriminative pathology signals, yet exhibit severe dimensional concentration.<n>We propose textbfAdaRAG-CT, an adaptive augmentation framework that compensates for this visual bottleneck.<n>AdaRAG-CT achieves state-of-the-art clinical efficacy, improving Clinical F1 from 0.420 (CT-Agent) to 0.480 (+6 points)
arXiv Detail & Related papers (2026-03-16T18:56:14Z) - A WDLoRA-Based Multimodal Generative Framework for Clinically Guided Corneal Confocal Microscopy Image Synthesis in Diabetic Neuropathy [8.701084151107652]
Corneal Confocal Microscopy is a sensitive tool for assessing small-fiber damage in Diabetic Peripheral Neuropathy (DPN)<n>Development of robust, automated deep learning-based diagnostic models is limited by scarce labelled data and fine-grained variability in corneal nerve morphology.<n>We propose a Weight-Decomposed Low-Rank Adaptation (WDLoRA)-based multimodal generative framework for clinically guided CCM image synthesis.
arXiv Detail & Related papers (2026-02-14T09:32:44Z) - EqDiff-CT: Equivariant Conditional Diffusion model for CT Image Synthesis from CBCT [43.92108185590778]
Cone-beam computed tomography (CBCT) is widely used for imageguided radiotherapy (IGRT)<n>We propose a novel diffusion-based conditional generative model, coined EqDiff-CT, to synthesize high-quality CT images from CBCT.
arXiv Detail & Related papers (2025-09-26T05:51:59Z) - Radiology Report Conditional 3D CT Generation with Multi Encoder Latent diffusion Model [0.830525411228399]
Report2CT is a conditional diffusion framework for synthesizing 3D chest CT volumes directly from free text radiology reports.<n>Report2CT generates anatomically consistent CT volumes with excellent visual quality and text image alignment.
arXiv Detail & Related papers (2025-09-18T09:32:23Z) - Towards a Benchmark for Colorectal Cancer Segmentation in Endorectal Ultrasound Videos: Dataset and Model Development [59.74920439478643]
In this paper, we collect and annotated the first benchmark dataset that covers diverse ERUS scenarios.
Our ERUS-10K dataset comprises 77 videos and 10,000 high-resolution annotated frames.
We introduce a benchmark model for colorectal cancer segmentation, named the Adaptive Sparse-context TRansformer (ASTR)
arXiv Detail & Related papers (2024-08-19T15:04:42Z) - CathFlow: Self-Supervised Segmentation of Catheters in Interventional Ultrasound Using Optical Flow and Transformers [66.15847237150909]
We introduce a self-supervised deep learning architecture to segment catheters in longitudinal ultrasound images.
The network architecture builds upon AiAReSeg, a segmentation transformer built with the Attention in Attention mechanism.
We validated our model on a test dataset, consisting of unseen synthetic data and images collected from silicon aorta phantoms.
arXiv Detail & Related papers (2024-03-21T15:13:36Z) - CIS-UNet: Multi-Class Segmentation of the Aorta in Computed Tomography
Angiography via Context-Aware Shifted Window Self-Attention [10.335899694123711]
We introduce Context Infused Swin-UNet (CIS-UNet), a deep learning model for aortic segmentation.
CIS-UNet adopts a hierarchical encoder-decoder structure comprising a CNN encoder, symmetric decoder, skip connections, and a novel Context-aware Shifted Window Self-Attention (CSW-SA) as the bottleneck block.
We trained our model on computed tomography (CT) scans from 44 patients and tested it on 15 patients. CIS-UNet outperformed the state-of-the-art SwinUNetR segmentation model, by achieving a superior mean Dice coefficient of 0.713 compared
arXiv Detail & Related papers (2024-01-23T19:17:20Z)
This list is automatically generated from the titles and abstracts of the papers in this site.
This site does not guarantee the quality of this site (including all information) and is not responsible for any consequences.