ViT3Flow: A Test-Time Training Transformer MeanFlow for Postoperative Radiograph Synthesis in Scoliosis
- URL: http://arxiv.org/abs/2609.05579v1
- Date: Fri, 04 Sep 2026 12:14:33 GMT
- Title: ViT3Flow: A Test-Time Training Transformer MeanFlow for Postoperative Radiograph Synthesis in Scoliosis
- Abstract summary: We formulate this problem as postoperative scoliosis radiograph synthesis and construct ScoliSurg, the first paired dataset for this task.<n>We propose ViT$3$Flow, a single-NFE conditional MeanFlow framework for efficient postoperative radiograph synthesis.
- Score: 24.805863115698475
- License: http://arxiv.org/licenses/nonexclusive-distrib/1.0/
- Abstract: Predicting postoperative spinal morphology from preoperative radiographs could provide valuable support for scoliosis surgical planning, but remains challenging because surgical correction induces large spatial changes while anatomical structures must be faithfully retained. We formulate this problem as postoperative scoliosis radiograph synthesis and construct ScoliSurg, the first paired dataset for this task, comprising 632 preoperative--postoperative whole-spine radiograph pairs with structured morphology information. We further propose ViT$^{3}$Flow, a single-NFE conditional MeanFlow framework for efficient postoperative radiograph synthesis. ViT$^{3}$Flow models surgical correction as finite-interval generative transport and replaces conventional self-attention with test-time-training token mixers that perform sample-specific inner adaptation to the anatomy and deformity pattern of each case. In addition, a Spinal Morphology Extraction Agent extracts distributions of dominant-curve region and direction from the preoperative radiograph. These distributions guide Diagnosis-Routed Interval Cross-Attention (DRICA), which performs interval-dependent vertical, horizontal, joint, and global retrieval from a separate preoperative token stream. This design enables the evolving postoperative representation to incorporate spatially corresponding anatomical evidence throughout the transport process. Extensive experiments on ScoliSurg demonstrate that ViT$^{3}$Flow achieves the best performance among the compared methods in perceptual image quality, anatomical fidelity, and clinically relevant geometric accuracy, while requiring only a single network evaluation. These results highlight the potential of ViT$^{3}$Flow for efficient and anatomically faithful postoperative radiograph synthesis in scoliosis surgical planning.
Related papers
- THA-Flow Generative Model: Prosthesis Geometry Prediction from Preoperative CT [7.351430886602578]
We present THA-Flow, a conditional flow-matching model that generates three-dimensional prosthesis geometry directly from preoperative CT.<n>Separate AutoencoderKL models compress preoperative bone anatomy and prosthesis geometry, while a three-dimensional UNet learns a rectified flow from Gaussian noise to the prosthesis latent space.
arXiv Detail & Related papers (2026-08-26T14:22:06Z) - Evidence-Based Text-Conditioned 3D CT Synthesis for Ovarian Cancer [9.862634656196759]
Ovarian cancer is frequently diagnosed at an advanced stage, making preoperative contrast-enhanced computed tomography (CT) central to staging and surgical planning.<n>Text-conditioned 3D CT synthesis has shown promise, but existing pipelines depend on paired radiology reports and have been evaluated only on chest CT.<n>We propose OvESyn, a framework that constructs standardized Findings and Impression sections directly from CT-derived imaging descriptors and routine clinical metadata.
arXiv Detail & Related papers (2026-06-27T15:30:29Z) - Rendering Novel Views of MRI Using 3D Gaussian Splatting [54.6286495315908]
We adapt 3D Gaussian Splatting to form a reconstruction starting from sparse anisotropic MRIs, and imaging planes aligned with the anatomy relevant for clinical evaluation are then sampled and rendered.<n>The novel view plane is optimal for diagnostic radiological grading of the target anatomy, whereas the original MRI is not.
arXiv Detail & Related papers (2026-06-24T18:00:03Z) - VRXU-net: A Deep Learning Approach for Brain Ischemic Stroke Lesion Detection and Segmentation in T1W MRI [0.0]
This study introduces a novel VRU-Net architecture, derived from visual features, residual connections, and a U-shaped network, for detecting and segmenting ischemic stroke lesions in 3D magnetic resonance imaging scans.<n>To improve both performance and processing speed, a high-performance classifier is applied before the segmentation model in a sequential framework.<n>The proposed model is trained on the Anatomical Tracings of Lesions After Stroke dataset and outperforms state-of-the-art models in terms of accuracy and Dice coefficient.
arXiv Detail & Related papers (2026-05-20T18:44:08Z) - Semantic Segmentation for Preoperative Planning in Transcatheter Aortic Valve Replacement [61.573750959726475]
We consider medical guidelines for preoperative planning of the transcatheter aortic valve replacement (TAVR) and identify tasks that may be supported via semantic segmentation models.<n>We first derive fine-grained TAVR-relevant pseudo-labels from coarse-grained anatomical information, in order to train segmentation models and quantify how well they are able to find these structures in the scans.
arXiv Detail & Related papers (2025-07-22T13:24:45Z) - Landmark-Free Preoperative-to-Intraoperative Registration in Laparoscopic Liver Resection [50.388465935739376]
Liver registration by overlaying preoperative 3D models onto intraoperative 2D frames can assist surgeons in perceiving the spatial anatomy of the liver clearly for a higher surgical success rate.<n>Existing registration methods rely heavily on anatomical landmark-based, which encounter two major limitations.<n>We propose a landmark-free preoperative-to-intraoperative registration framework utilizing effective self-supervised learning.
arXiv Detail & Related papers (2025-04-21T14:55:57Z) - CathFlow: Self-Supervised Segmentation of Catheters in Interventional Ultrasound Using Optical Flow and Transformers [66.15847237150909]
We introduce a self-supervised deep learning architecture to segment catheters in longitudinal ultrasound images.
The network architecture builds upon AiAReSeg, a segmentation transformer built with the Attention in Attention mechanism.
We validated our model on a test dataset, consisting of unseen synthetic data and images collected from silicon aorta phantoms.
arXiv Detail & Related papers (2024-03-21T15:13:36Z) - Domain adaptation strategies for 3D reconstruction of the lumbar spine using real fluoroscopy data [9.21828361691977]
This study tackles key obstacles in adopting surgical navigation in orthopedic surgeries.
It shows an approach for generating 3D anatomical models of the spine from only a few fluoroscopic images.
It achieved an 84% F1 score, matching the accuracy of our previous synthetic data-based research.
arXiv Detail & Related papers (2024-01-29T10:22:45Z) - AiAReSeg: Catheter Detection and Segmentation in Interventional
Ultrasound using Transformers [75.20925220246689]
endovascular surgeries are performed using the golden standard of Fluoroscopy, which uses ionising radiation to visualise catheters and vasculature.
This work proposes a solution using an adaptation of a state-of-the-art machine learning transformer architecture to detect and segment catheters in axial interventional Ultrasound image sequences.
arXiv Detail & Related papers (2023-09-25T19:34:12Z) - Tattoo tomography: Freehand 3D photoacoustic image reconstruction with
an optical pattern [49.240017254888336]
Photoacoustic tomography (PAT) is a novel imaging technique that can resolve both morphological and functional tissue properties.
A current drawback is the limited field-of-view provided by the conventionally applied 2D probes.
We present a novel approach to 3D reconstruction of PAT data that does not require an external tracking system.
arXiv Detail & Related papers (2020-11-10T09:27:56Z)
This list is automatically generated from the titles and abstracts of the papers in this site.
This site does not guarantee the quality of this site (including all information) and is not responsible for any consequences.