Video-based detection of cessation of breathing in pre-term infants using machine learning
- URL: http://arxiv.org/abs/2607.05230v1
- Date: Mon, 06 Jul 2026 15:42:21 GMT
- Title: Video-based detection of cessation of breathing in pre-term infants using machine learning
- Abstract summary: We investigated whether camera-based signals can detect apnoea-related cessation of breathing.<n>Using video and clinical recordings from 30 pre-term infants, respiratory motion was extracted from dynamically tracked torso regions.<n>Camera-only models achieved a balanced accuracy of 76.9%, demonstrating the feasibility of non-contact COBE detection.
- Score: 1.8148201112091653
- License: http://creativecommons.org/licenses/by/4.0/
- Abstract: Pre-term infants are susceptible to potentially harmful apnoea-related cessations of breathing due to immature respiratory control. However, reliable respiratory monitoring in the neonatal intensive care unit (NICU) remains challenging because motion artefacts, sensor displacement, and skin fragility can compromise contact-based measurements. Non-contact video monitoring offers a complementary approach that does not depend on adhesive sensors while providing additional respiratory information. We investigated whether camera-based signals can detect apnoea-related cessation of breathing (COBE) and provide complementary information to routinely acquired physiological signals. Using video and clinical recordings from 30 pre-term infants, respiratory motion was extracted from dynamically tracked torso regions to generate camera-derived time-series signals. Camera-only models were trained using residual network (ResNet) architectures, while hybrid models combined video-derived signals with impedance pneumography (IP), ECG-derived respiration (EDR), and the PPG-derived respiratory envelope. Camera-only models achieved a balanced accuracy of 76.9%, demonstrating the feasibility of non-contact COBE detection. Combining video-derived features with IP improved balanced accuracy to 90.6%, outperforming either modality alone and indicating that video provides respiratory information beyond standard physiological signals. These findings show that video-derived signals contain clinically relevant respiratory features and enhance COBE detection when combined with conventional physiological signals. This supports non-contact video as a complementary modality for automated COBE detection and highlights its potential to improve the robustness of neonatal respiratory monitoring.
Related papers
- A Low-Power Wearable Respiratory Sensor for Non-Invasive Stress Monitoring [0.5416422382471174]
We present a compact non-invasive respiratory sensing system based on a force-sensitive resistor embedded in an abdominal belt.<n>We evaluate the complete sensing pipeline across multiple breathing patterns and body positions.<n>Our results show that the proposed platform enables real-time respiratory monitoring across diverse daily-life scenarios.
arXiv Detail & Related papers (2026-08-06T07:41:34Z) - Deep learning-based detection of cessation of breathing in pre-term infants [1.8148201112091653]
Apnoea of prematurity is difficult to detect reliably using routinely monitored physiological signals.<n>We evaluated deep learning-based detection of apnoea-related Cessation Of BrEathing events.
arXiv Detail & Related papers (2026-06-22T11:56:50Z) - Towards Athlete Fatigue Assessment from Association Football Videos [53.20057980542362]
This paper builds on state-of-theart Game State Reconstruction methods to extract player trajectories in pitch coordinates.<n>We then construct acceleration--speed profiles from these signals and analyze their behavior as fatigue-related performance indicators.<n>Our results indicate that monocular broadcast videos can recover kinematic patterns that are compatible with A-S-temporal while also revealing sensitivity to trajectory noise, calibration errors, and temporal discontinuities inherent to broadcast footage.
arXiv Detail & Related papers (2026-04-07T09:36:28Z) - Respiratory Status Detection with Video Transformers [1.1101763410958634]
We evaluate whether recent advances in video transformers can enable Artificial Intelligence systems to recognize the signs of respiratory distress from video.<n>Our findings suggest that modern video transformers can recognize subtle changes in respiratory mechanics.
arXiv Detail & Related papers (2026-03-22T18:16:18Z) - Recovering Pulse Waves from Video Using Deep Unrolling and Deep Equilibrium Models [45.94962431110573]
Camera-based monitoring of vital signs, also known as imaging photoplethysmography (i), has seen applications in driver-monitoring, affective computing, and more.<n>We introduce methods that combine signal processing and deep learning methods in an inverse problem.
arXiv Detail & Related papers (2025-03-21T16:11:21Z) - Machine learning-based algorithms for at-home respiratory disease monitoring and respiratory assessment [45.104212062055424]
This work aims to develop machine learning-based algorithms to facilitate at-home respiratory disease monitoring and assessment.
Data were collected from 30 healthy adults, encompassing respiratory pressure, flow, and dynamic thoraco-abdominal circumferential measurements.
Various machine learning models, including the random forest classifier, logistic regression, and support vector machine (SVM), were trained to predict breathing types.
arXiv Detail & Related papers (2024-09-05T02:14:31Z) - Analyzing Participants' Engagement during Online Meetings Using Unsupervised Remote Photoplethysmography with Behavioral Features [50.82725748981231]
Engagement measurement finds application in healthcare, education, services.
Use of physiological and behavioral features is viable, but impracticality of traditional physiological measurement arises due to the need for contact sensors.
We demonstrate the feasibility of the unsupervised photoplethysmography (rmography) as an alternative for contact sensors.
arXiv Detail & Related papers (2024-04-05T20:39:16Z) - Automatic Infant Respiration Estimation from Video: A Deep Flow-based
Algorithm and a Novel Public Benchmark [10.097634735211654]
We develop a deep-learning method for estimating respiratory rate and waveform from plain video footage in natural settings.
Our model supports the first public annotated infant respiration dataset with 125 videos.
When trained and tested on the AIR-125 infant data, our method significantly outperforms other state-of-the-art methods in respiratory rate estimation.
arXiv Detail & Related papers (2023-07-24T19:59:15Z) - Using BOLD-fMRI to Compute the Respiration Volume per Time (RTV) and
Respiration Variation (RV) with Convolutional Neural Networks (CNN) in the
Human Connectome Development Cohort [55.41644538483948]
This study proposes a one-dimensional CNN model for reconstruction of two respiratory measures, RV and RVT.
Results show that a CNN can capture informative features from resting BOLD signals and reconstruct realistic RV and RVT timeseries.
arXiv Detail & Related papers (2023-07-03T18:06:36Z) - Identification of deep breath while moving forward based on multiple
body regions and graph signal analysis [45.62293065676075]
This paper presents an unobtrusive solution that can automatically identify deep breath when a person is walking past the global depth camera.
In validation experiments, the proposed approach outperforms the comparative methods with the accuracy, precision, recall and F1 of 75.5%, 76.2%, 75.0% and 75.2%, respectively.
arXiv Detail & Related papers (2020-10-20T08:26:50Z) - Wearable Respiration Monitoring: Interpretable Inference with Context
and Sensor Biomarkers [5.065947993017157]
Breathing rate (BR), minute ventilation (VE), and other respiratory parameters are essential for real-time patient monitoring in many acute health conditions, such as asthma.
In this work, we infer respiratory parameters from wearable ECG and wrist motion signals.
arXiv Detail & Related papers (2020-07-02T22:12:49Z) - Multispectral Video Fusion for Non-contact Monitoring of Respiratory
Rate and Apnea [7.300192965401497]
Non-contact monitoring of respiration can be achieved with near- and far-infrared spectrum cameras.
We present a novel algorithm based on multispectral data fusion that aims at estimating respiratory rate (RR) during apnea.
Our findings may represent a step towards the use of cameras for vital sign monitoring in medical applications.
arXiv Detail & Related papers (2020-04-21T09:07:09Z)
This list is automatically generated from the titles and abstracts of the papers in this site.
This site does not guarantee the quality of this site (including all information) and is not responsible for any consequences.