Eversion-based robots can enable safe access,steering and endoscopic imaging within the spinal subarachnoid space
- URL: http://arxiv.org/abs/2607.19274v1
- Date: Tue, 21 Jul 2026 16:46:00 GMT
- Title: Eversion-based robots can enable safe access,steering and endoscopic imaging within the spinal subarachnoid space
- Abstract summary: We present a 2 mm diameter eversion-growing robotic platform that enables friction minimised extension and steering within the human spinal subarachnoid space.<n>The robot integrates a miniature endoscope for real time intrathecal visualisation and advances by pressure driven tip eversion.<n>In an intact human cadaver, the system achieved 150 mm of controlled intrathecal extension with concurrent fluoroscopic and endoscopic visualisation.
- Score: 7.4000506819669845
- License: http://creativecommons.org/licenses/by/4.0/
- Abstract: Safe navigation within the spinal subarachnoid space is constrained by its narrow, compliant, and delicate anatomy. Conventional catheters and continuum robots rely on proximal pushing, generating friction and shear along the tissue device interface that limit distal controllability and increase the risk of neural injury. Here, we present a 2 mm diameter eversion-growing robotic platform that enables friction minimised extension and steering within the human spinal subarachnoid space, validated through computational modelling, phantom experiments, and intact human cadaver studies. The robot integrates a miniature endoscope for real time intrathecal visualisation and advances by pressure driven tip eversion, localising motion to the distal tip while minimising translational sliding of the deployed body. Phantom experiments demonstrated reductions of 65.2% in mean interaction force and 48.0% in peak interaction force compared with matched push-based insertion. Physics based modelling showed that eversion based growth redistributed tissue loading, reducing local stress concentrations and interfacial shear relative to conventional insertion. In an intact human cadaver, the system achieved 150 mm of controlled intrathecal extension with concurrent fluoroscopic and endoscopic visualisation, providing access across multiple vertebral levels from a standard lumbar entry point. Postprocedural laminectomy and durotomy revealed no observable macroscopic disruption of the dura mater or surrounding neural structures. These results provide the first mechanically characterised and multimodally validated demonstration of eversion-based robotic navigation in intact human spinal anatomy, establishing a quantitative and procedural foundation for future intrathecal interventions. Further validation in larger anatomical cohorts and under physiological conditions will be required before clinical translation.
Related papers
- Modular Robotic Catheters for Endovascular Aneurysm Repair [55.52876285801259]
endovascular aneurysm repair require surgeons to navigate catheters and guidewires into various branches of the abdominal aorta.<n>Previous clinical studies suggest that surgeons continue to struggle with vessel access using standard commercial instruments.<n>We present two contributions to solving this problem: 1) A bespoke 2-segment steerable catheter, consisting of 4 degrees of freedom to enhance dexterity.
arXiv Detail & Related papers (2026-07-28T14:53:03Z) - A Compact Top-Loading Robot for Endovascular Interventions: Design, Control and Evaluation [10.95060747006468]
Robot-assisted endovascular intervention can potentially reduce radiation exposure, improve surgeon ergonomics, enable telesurgery, and enhance procedural precision.<n>Existing systems often suffer from limited procedural coverage because constrained patient-side setups, restricted flexibility, and complex instrument exchange hinder clinical workflow integration.<n>This work presents a compact robotic system for endovascular interventions that enables continuous translational and rotational manipulation of standard endovascular instruments.
arXiv Detail & Related papers (2026-07-13T16:35:14Z) - Fluoroscopy-Constrained Magnetic Robot Control via Zernike-Based Field Modeling and Nonlinear MPC [4.093982213892736]
Magnetic actuation enables surgical robots to navigate complex anatomical pathways while reducing tissue trauma and improving surgical precision.<n>This paper presents a control framework that remains accurate and stable under such conditions by combining a nonlinear model predictive control framework.<n> Experimental validation is conducted with two magnetic robots in a 3D-printed fluid workspace and a spine phantom replicating drug delivery in the epidural space.
arXiv Detail & Related papers (2026-02-17T04:50:18Z) - Moving Beyond Compliance in Soft-Robotic Catheters Through Modularity for Precision Therapies [0.0]
Soft robotic instruments could navigate delicate, tortuous anatomy more safely than rigid tools.<n>Few sensing and therapeutic modules are compact, robust, and adaptable enough to measure, and respond to, subtle physiological cues during intraluminal procedures.<n>We present a 1.47 mm diameter modular soft robotic catheter that integrates sensing, actuation, and therapy while retaining the compliance needed for safe endoluminal navigation.
arXiv Detail & Related papers (2026-01-21T10:11:59Z) - Helical Tendon-Driven Continuum Robot with Programmable Follow-the-Leader Operation [0.11242503819703255]
The ExoNav is a steerable robotic tool designed to facilitate precise navigation to the ventral and lateral epidural space.<n>Based on the helical shape of the ExoNav upon actuation, it is capable of performing follow-the-leader (FTL) motion.<n>The proposed simulation has the capability to calculate optimum tendon tensions to follow the desired FTL paths.
arXiv Detail & Related papers (2026-01-19T16:03:56Z) - Reinforcement Learning for Follow-the-Leader Robotic Endoscopic Navigation via Synthetic Data [21.611096590329343]
We present a follow-the-leader endoscopic robot based on a flexible continuum structure designed to minimize contact between the endoscope body and intestinal walls.<n>We propose a vision-based deep reinforcement learning framework guided by monocular depth estimation.
arXiv Detail & Related papers (2026-01-06T08:15:53Z) - Intraoperative Registration by Cross-Modal Inverse Neural Rendering [61.687068931599846]
We present a novel approach for 3D/2D intraoperative registration during neurosurgery via cross-modal inverse neural rendering.
Our approach separates implicit neural representation into two components, handling anatomical structure preoperatively and appearance intraoperatively.
We tested our method on retrospective patients' data from clinical cases, showing that our method outperforms state-of-the-art while meeting current clinical standards for registration.
arXiv Detail & Related papers (2024-09-18T13:40:59Z) - EyeLS: Shadow-Guided Instrument Landing System for Intraocular Target
Approaching in Robotic Eye Surgery [51.05595735405451]
Robotic ophthalmic surgery is an emerging technology to facilitate high-precision interventions such as retina penetration in subretinal injection and removal of floating tissues in retinal detachment.
Current image-based methods cannot effectively estimate the needle tip's trajectory towards both retinal and floating targets.
We propose to use the shadow positions of the target and the instrument tip to estimate their relative depth position.
Our method succeeds target approaching on a retina model, and achieves an average depth error of 0.0127 mm and 0.3473 mm for floating and retinal targets respectively in the surgical simulator.
arXiv Detail & Related papers (2023-11-15T09:11:37Z) - AiAReSeg: Catheter Detection and Segmentation in Interventional
Ultrasound using Transformers [75.20925220246689]
endovascular surgeries are performed using the golden standard of Fluoroscopy, which uses ionising radiation to visualise catheters and vasculature.
This work proposes a solution using an adaptation of a state-of-the-art machine learning transformer architecture to detect and segment catheters in axial interventional Ultrasound image sequences.
arXiv Detail & Related papers (2023-09-25T19:34:12Z) - fMRI from EEG is only Deep Learning away: the use of interpretable DL to
unravel EEG-fMRI relationships [68.8204255655161]
We present an interpretable domain grounded solution to recover the activity of several subcortical regions from multichannel EEG data.
We recover individual spatial and time-frequency patterns of scalp EEG predictive of the hemodynamic signal in the subcortical nuclei.
arXiv Detail & Related papers (2022-10-23T15:11:37Z) - Towards Autonomous Atlas-based Ultrasound Acquisitions in Presence of
Articulated Motion [48.52403516006036]
This paper proposes a vision-based approach allowing autonomous robotic US limb scanning.
To this end, an atlas MRI template of a human arm with annotated vascular structures is used to generate trajectories.
In all cases, the system can successfully acquire the planned vascular structure on volunteers' limbs.
arXiv Detail & Related papers (2022-08-10T15:39:20Z) - Microvascular Dynamics from 4D Microscopy Using Temporal Segmentation [81.30750944868142]
We are able to track changes in cerebral blood volume over time and identify spontaneous arterial dilations that propagate towards the pial surface.
This new imaging capability is a promising step towards characterizing the hemodynamic response function upon which functional magnetic resonance imaging (fMRI) is based.
arXiv Detail & Related papers (2020-01-14T22:55:03Z)
This list is automatically generated from the titles and abstracts of the papers in this site.
This site does not guarantee the quality of this site (including all information) and is not responsible for any consequences.