Measurements Automatically Extracted from Zero Echo Time MRI Using Deep Learning Image Segmentation and Geometric Modeling Agree with Expert Manual Readings
- URL: http://arxiv.org/abs/2608.07368v1
- Date: Fri, 07 Aug 2026 16:11:11 GMT
- Title: Measurements Automatically Extracted from Zero Echo Time MRI Using Deep Learning Image Segmentation and Geometric Modeling Agree with Expert Manual Readings
- Abstract summary: We developed and validated automated FAI angle computation from ZTE MRI.<n>nnU-Net was trained on 100 manually curated hips to segment the femur, pelvis, and three osseous landmarks.
- Score: 0.0
- License: http://arxiv.org/licenses/nonexclusive-distrib/1.0/
- Abstract: Computed tomography (CT) remains the reference for 3D osseous morphometry in femoroacetabular impingement (FAI) but requires ionizing radiation and manual measurement. Zero echo time (ZTE) MRI visualizes cortical bone and yields FAI angles that agree with CT, but automated angle extraction remains limited. We developed and validated automated FAI angle computation from ZTE MRI and assessed agreement with expert manual measurements in a cross-sectional study (level of evidence, 3). Pelvic ZTE MRI was acquired in 73 participants (mean age 36.8 +/- 18.5 years; 51 women, 22 men), yielding 135 hips. nnU-Net was trained on 100 manually curated hips to segment the femur, pelvis, and three osseous landmarks. Custom geometric algorithms computed alpha, femoral neck-shaft, Tonnis, coronal and sagittal center-edge, and acetabular version angles from inferred segmentations. Measurements on 35 test hips were compared with the mean of two radiologists' manual measures using intraclass correlation (ICC) and Bland-Altman analysis. Dice exceeded 0.96 for bone and ranged from 0.65 to 0.83 for landmarks. Median landmark error was 0.38 mm (femoral head), 0.82 mm (lateral acetabulum), and <2.5 mm (medial acetabulum, greater trochanter). Interrater ICC was excellent for acetabular version, coronal center-edge, and Tonnis (>=0.82) but poor for alpha and femoral neck-shaft. Model versus rater-mean agreement was excellent for acetabular version, coronal center-edge, and Tonnis (0.92-0.96), good for mid-acetabular sagittal center-edge (0.74), and fair for alpha (0.45) and femoral neck-shaft (0.55). Model Bland-Altman limits of agreement were narrower than interrater limits for most angles. Fully automated morphometric assessment from ZTE MRI is feasible and performs comparably to expert readers for most coverage and version angles.
Related papers
- TriALS: Triphasic-Aided Liver Lesion Segmentation Benchmark in Non-Contrast CT [49.93685997940356]
We describe the TriALS challenge for automated liver lesion segmentation under contrast-limited conditions.<n>The top-performing method achieved a mean venous-phase Dice of 0.754, consistent with human-level performance, yet dropped to 0.57 on NCCT.<n>Algorithm performance was most strongly predicted by training data scale and pre-training strategy.
arXiv Detail & Related papers (2026-05-15T19:23:35Z) - Automated glenoid bone loss measurement and segmentation in CT scans for pre-operative planning in shoulder instability [4.618498494409548]
Reliable measurement of glenoid bone loss is essential for operative planning in shoulder instability.<n>We developed and validated a fully automated deep learning pipeline for measuring glenoid bone loss on three-dimensional computed tomography (CT) scans.
arXiv Detail & Related papers (2025-11-18T03:12:22Z) - A Novel Attention-Augmented Wavelet YOLO System for Real-time Brain Vessel Segmentation on Transcranial Color-coded Doppler [49.03919553747297]
We propose an AI-powered, real-time CoW auto-segmentation system capable of efficiently capturing cerebral arteries.<n>No prior studies have explored AI-driven cerebrovascular segmentation using Transcranial Color-coded Doppler (TCCD)<n>The proposed AAW-YOLO demonstrated strong performance in segmenting both ipsilateral and contralateral CoW vessels.
arXiv Detail & Related papers (2025-08-19T14:41:22Z) - TissUnet: Improved Extracranial Tissue and Cranium Segmentation for Children through Adulthood [1.1144337101638346]
We present TissUnet, a deep learning model that segments skull bone, subcutaneous fat, and muscle from routine three-dimensional T1-weighted MRI.<n>The model was trained on 155 paired MRI- computed tomography (CT) scans and validated across nine datasets.
arXiv Detail & Related papers (2025-06-06T01:21:34Z) - Explainable Anatomy-Guided AI for Prostate MRI: Foundation Models and In Silico Clinical Trials for Virtual Biopsy-based Risk Assessment [3.5408411348831232]
We present a fully automated, anatomically guided deep learning pipeline for prostate cancer (PCa) risk stratification using routine MRI.<n>The pipeline integrates three key components: an nnU-Net module for segmenting the prostate gland and its zones on axial T2-weighted MRI; a classification module based on the DiceedPT Swin Transformer foundation model, fine-tuned on 3D patches with optional anatomical priors and clinical data; and a VAE-GAN framework for generating counterfactual heatmaps that localize decision-driving image regions.
arXiv Detail & Related papers (2025-05-23T14:40:09Z) - VIBESegmentator: Full Body MRI Segmentation for the NAKO and UK Biobank [13.370382898117226]
We present a publicly available deep learning-based torso segmentation model for MRI and CT images.<n>Our model ties with the best model on Amos with a Dice of 0,81+-0.14, while having a larger field of view and a considerably higher number structures included.
arXiv Detail & Related papers (2024-05-31T18:32:46Z) - TotalSegmentator MRI: Robust Sequence-independent Segmentation of Multiple Anatomic Structures in MRI [59.86827659781022]
A nnU-Net model (TotalSegmentator) was trained on MRI and segment 80atomic structures.<n>Dice scores were calculated between the predicted segmentations and expert reference standard segmentations to evaluate model performance.<n>Open-source, easy-to-use model allows for automatic, robust segmentation of 80 structures.
arXiv Detail & Related papers (2024-05-29T20:15:54Z) - MRISegmentator-Abdomen: A Fully Automated Multi-Organ and Structure Segmentation Tool for T1-weighted Abdominal MRI [12.236789438183138]
There is no publicly available abdominal MRI dataset with voxel-level annotations of multiple organs and structures.
A 3D nnUNet model, dubbed as MRISegmentator-Abdomen (MRISegmentator in short), was trained on this dataset.
The tool provides automatic, accurate, and robust segmentations of 62 organs and structures in T1-weighted abdominal MRI sequences.
arXiv Detail & Related papers (2024-05-09T17:33:09Z) - Accurate Fine-Grained Segmentation of Human Anatomy in Radiographs via
Volumetric Pseudo-Labeling [66.75096111651062]
We created a large-scale dataset of 10,021 thoracic CTs with 157 labels.
We applied an ensemble of 3D anatomy segmentation models to extract anatomical pseudo-labels.
Our resulting segmentation models demonstrated remarkable performance on CXR.
arXiv Detail & Related papers (2023-06-06T18:01:08Z) - Segmentation of the Myocardium on Late-Gadolinium Enhanced MRI based on
2.5 D Residual Squeeze and Excitation Deep Learning Model [55.09533240649176]
The aim of this work is to develop an accurate automatic segmentation method based on deep learning models for the myocardial borders on LGE-MRI.
A total number of 320 exams (with a mean number of 6 slices per exam) were used for training and 28 exams used for testing.
The performance analysis of the proposed ensemble model in the basal and middle slices was similar as compared to intra-observer study and slightly lower at apical slices.
arXiv Detail & Related papers (2020-05-27T20:44:38Z) - Machine-Learning-Based Multiple Abnormality Prediction with Large-Scale
Chest Computed Tomography Volumes [64.21642241351857]
We curated and analyzed a chest computed tomography (CT) data set of 36,316 volumes from 19,993 unique patients.
We developed a rule-based method for automatically extracting abnormality labels from free-text radiology reports.
We also developed a model for multi-organ, multi-disease classification of chest CT volumes.
arXiv Detail & Related papers (2020-02-12T00:59:23Z)
This list is automatically generated from the titles and abstracts of the papers in this site.
This site does not guarantee the quality of this site (including all information) and is not responsible for any consequences.