Distribution-free false-alarm calibration and chance-corrected spatial evaluation for industrial anomaly detection
- URL: http://arxiv.org/abs/2608.15090v1
- Date: Sat, 15 Aug 2026 07:21:05 GMT
- Title: Distribution-free false-alarm calibration and chance-corrected spatial evaluation for industrial anomaly detection
- Abstract summary: We combine a distribution-free upper tolerance threshold with a paired-minus-crossed spatial test.<n>We evaluate three detectors on 120 point-defect images from three ISP-AD modalities and three fixed data splits.
- Score: 2.5273986395975476
- License: http://arxiv.org/licenses/nonexclusive-distrib/1.0/
- Abstract: Studies of industrial visual inspection commonly report the area under the receiver operating characteristic curve (AUROC) and the overlap between anomaly maps and defect masks. Neither measure specifies the false-alarm rate at a selected threshold, while recurrent defect locations and mask geometry can inflate overlap. We combine a distribution-free upper tolerance threshold with a paired-minus-crossed spatial test. This test compares each detector's score-contributing locations with the matched defect mask and with masks from other images; the difference in rates defines spatial-evidence lift relative to the empirical chance-overlap rate. We evaluate three detectors on 120 point-defect images from three ISP-AD modalities and three fixed data splits. Of 378 alarms, 230 overlap the matched mask. Paired and crossed rates are nevertheless similar in eight of nine detector--modality cells; only DINOv2--ASM has a positive 95\% bootstrap lower bound (lift 0.259, 95\% interval 0.159--0.347). On the independent Magnetic Tile Defect dataset, the same analysis gives lifts of 0.203 (0.169--0.236) for Wide ResNet-50 (WRN50) patch memory and 0.231 (0.202--0.262) for Vision Transformer B/16 (ViT-B/16) patch memory, with one-sided permutation $p=10^{-5}$ for both. When crossed masks are restricted to the same defect class, the lifts remain 0.185 and 0.210. Exact sample planning shows that, with 150 calibration normals, a 95\%-confidence distribution-free claim is supported only for target false-positive rates of 1.98\% or higher; a 1\% target requires at least 299 normals. The results support reporting operating-point performance and chance-corrected spatial evidence alongside AUROC and raw mask overlap.
Related papers
- Not All Relations Are Equal: Relation-Balanced and Calibrated Graph Learning for Provenance-Based Intrusion Detection [66.44527094471619]
We present RECAL, an unsupervised framework using relation-balanced masked graph learning to better capture rare interaction patterns.<n>On three DARPA E3 datasets, RECAL achieves F1 scores of 99.99%, 99.93%, and 99.99%, outperforming the best baseline on each dataset by 0.88, 0.82, and 0.42 percentage points, respectively.
arXiv Detail & Related papers (2026-09-15T00:31:01Z) - SHIFT-M3: Pre-fusion Alignment-based Consistency Screening for Multimodal ECG Record Integrity [0.0]
Multimodal clinical AI typically assumes that the waveform, report, metadata, and downstream predictions attached to a record belong to the same patient.<n>We study this problem as multimodal record integrity triage: given an assembled record, should its modalities be trusted to belong together?<n>We introduce SHIFT-M3, a lightweight text-based pre-fusion screen that measures alignment-based consistency between two separately produced ECG text views.
arXiv Detail & Related papers (2026-09-12T10:58:02Z) - Drift Calibration in Geometric Eye Tracking Systems [34.12106856838315]
We present a calibration-focused dataset containing 163 trials from 12 participants.<n>We use it to evaluate global, local, and composite correction functions under a common spatial-extrapolation protocol.
arXiv Detail & Related papers (2026-08-30T12:05:44Z) - RibAssist 3D: Biplanar Rib-Fracture Detection, Addressing, and Selective 3D Localization from CT-Derived Projections [0.6768558752130311]
Rib fractures are common and time-consuming to localize on computed tomography (CT)<n>We ask whether fractures detected independently in two orthogonal CT-derived projections can be paired across views and triangulated into reliable 3D points at a controlled rate of false outputs.<n>The study establishes a reproducible framework for selective 3D localization and identifies cross-view correspondence as the dominant operational bottleneck.
arXiv Detail & Related papers (2026-08-07T07:47:20Z) - A Few Neurons Reveal When LLMs Misuse Tools: Sparse Detection and Selective Steering for Reliable Tool Use [28.57781785937644]
We introduce PRISMS (Probing Representations In Support of Monitoring and Steering), a closed-loop framework that shares a failure-specific neuron basis between sparse detection and activation.<n>Across six models, PRISMS reduces pooled over-calling rate by 80% while increasing tool-required accuracy by 14.2 percentage points.
arXiv Detail & Related papers (2026-07-31T19:03:44Z) - VESTIGE: A Knowledge-Guided Masking Strategy for Corruption-Aware Fine-Tuning of Genomic Transformers, Validated on Ancient DNA Reconstruction [0.0]
Masked--model fine-tuning applies a uniform masking probability across every token position, assuming reconstruction difficulty is position-agnostic.<n>We introduce VESTIGE, a parameter-free, drop-in replacement for the standard collator that aligns the masking distribution with an empirically measured per-position corruption profile.
arXiv Detail & Related papers (2026-07-30T05:47:47Z) - Level, Sharpness, and Corpus: Why Zero-Shot OOD Detector Rankings Do Not Transfer [36.02174685737611]
We find that detector rankings reverse across deployments, every detector exceeds $80%$ FPR95 on at least one domain, and the preferred detector depends on both the in-distribution data and the underlying VLM.<n>We introduce the Complementary Evidence Guard (CEG), a detector-agnostic wrapper that preserves complementary evidence through a non-compensatory fusion of the base detector, level, and sharpness.
arXiv Detail & Related papers (2026-07-29T08:00:49Z) - Specificity- and Calibration-Aware Breast Ultrasound Segmentation via Entropy-Guided Boundary Supervision [0.0]
In images with lesions, speckle noise, low tissue contrast, and posterior acoustic shadowing cause boundary leakage and incomplete contour delineation.<n>This study addresses both failure modes through a single modification to the training objective.<n>Rather than weighting every boundary pixel equally, the proposed loss scales contour penalties by per-pixel predictive entropy and the ground-truth boundary map.
arXiv Detail & Related papers (2026-06-21T02:21:11Z) - Online Shift Detection and Conformal Adaptation for Deployed Safety Classifiers [0.0]
We present an online monitoring system for distributional shift in deployed safety classifiers.<n>After detection, a conformal abstention layer adapts decision to recover a target error.<n>The system achieves 86.6% detection with mean latency of 39.5800 steps.
arXiv Detail & Related papers (2026-06-10T11:24:25Z) - Efficient Transformer-Based Localized Patch Sampling for Choroid Plexus Segmentation in Multiple Sclerosis [26.831715552066694]
The lateral ventricle choroid plexus (LVCP) is gaining recognition as a key imaging biomarker for multiple sclerosis (MS) related to physical disability and neuroinflammation.<n>This research aims to develop a SwinUNETR-driven pipeline that automatically segment the LVCP in MS from both standalone and multi-modal MRI inputs.
arXiv Detail & Related papers (2026-06-02T12:32:43Z) - Amplifying, Not Learning: Fine-Tuned AI Text Detectors Amplify a Pretrained Direction [51.56484100374058]
Text detectors amplify a pretrained typicality axis; they do not construct an AI-vs-human boundary.<n>On raw encoders before any task supervision, projecting onto centroid(AI)-centroid(HC3) achieves NYT-vs-HC3 AUROC 0.806/0.944/0.834 across three architectures.<n>On RoBERTa-base, raw projection exceeds fine-tuning; on RoBERTa-base, full fine-tuning reduces discrimination below raw on both fluent-formal populations tested.
arXiv Detail & Related papers (2026-05-20T19:08:38Z) - Impact of Labeling Inaccuracy and Image Noise on Tooth Segmentation in Panoramic Radiographs using Federated, Centralized and Local Learning [46.232038247686745]
Federated learning (FL) may mitigate privacy constraints, heterogeneous data quality, and inconsistent labeling in dental diagnostic AI.<n>We compared FL with centralized (CL) and local learning (LL) for tooth segmentation in panoramic radiographs across multiple data corruption scenarios.
arXiv Detail & Related papers (2025-09-08T11:07:47Z) - Automated Pulmonary Embolism Detection from CTPA Images Using an
End-to-End Convolutional Neural Network [31.58557856188164]
This study presents an end-to-end trainable convolutional neural network (CNN) for detecting pulmonary embolisms (PEs)
Our system achieves a sensitivity of 63.2%, 78.9% and 86.8% at 2 false positives per volume at 0mm, 2mm and 5mm localization error.
arXiv Detail & Related papers (2021-11-10T03:01:55Z)
This list is automatically generated from the titles and abstracts of the papers in this site.