Disassemblable Fieldwork CT Scanner Using a 3D-printed Calibration
Phantom
- URL: http://arxiv.org/abs/2011.06671v1
- Date: Thu, 12 Nov 2020 22:07:29 GMT
- Title: Disassemblable Fieldwork CT Scanner Using a 3D-printed Calibration
Phantom
- Abstract summary: We introduce a low-cost disassemblable CT scanner that allows calibration even when trajectory reproduction is not possible.
Using 3D-printed in-image calibration phantoms, we compute a projection matrix directly from each captured X-ray projection.
- Score: 8.963422124274095
- License: http://creativecommons.org/licenses/by/4.0/
- Abstract: The use of computed tomography (CT) imaging has become of increasing interest
to academic areas outside of the field of medical imaging and industrial
inspection, e.g., to biology and cultural heritage research. The pecularities
of these fields, however, sometimes require that objects need to be imaged
on-site, e.g., in field-work conditions or in museum collections. Under these
circumstances, it is often not possible to use a commercial device and a custom
solution is the only viable option. In order to achieve high image quality
under adverse conditions, reliable calibration and trajectory reproduction are
usually key requirements for any custom CT scanning system. Here, we introduce
the construction of a low-cost disassemblable CT scanner that allows
calibration even when trajectory reproduction is not possible due to the
limitations imposed by the project conditions. Using 3D-printed in-image
calibration phantoms, we compute a projection matrix directly from each
captured X-ray projection. We describe our method in detail and show successful
tomographic reconstructions of several specimen as proof of concept.
Related papers
- 6D Robotic OCT Scanning of Curved Tissue Surfaces [41.08297278009004]
We propose a marker for full six-dimensional hand-eye calibration of a robot mounted OCT probe.<n>We show that the calibration results in highly repeatable estimates of the transformation.<n>We also demonstrate that the proposed calibration allows for consistent scanning of large, curved tissue surfaces.
arXiv Detail & Related papers (2026-03-23T14:24:11Z) - Accelerating 3D Photoacoustic Computed Tomography with End-to-End Physics-Aware Neural Operators [74.65171736966131]
Photoacoustic computed tomography (PACT) combines optical contrast with ultrasonic resolution, achieving deep-tissue imaging beyond the optical diffusion limit.<n>Current implementations require dense transducer arrays and prolonged acquisition times, limiting clinical translation.<n>We introduce Pano, an end-to-end physics-aware model that directly learns the inverse acoustic mapping from sensor measurements to volumetric reconstructions.
arXiv Detail & Related papers (2025-09-11T23:12:55Z) - Fan-Beam CT Reconstruction for Unaligned Sparse-View X-ray Baggage Dataset [0.0]
We present a calibration and reconstruction method using an unaligned sparse multi-view X-ray baggage dataset.
Our approach integrates multi-spectral neural attenuation field reconstruction with Linear pushbroom (LPB) camera model pose optimization.
arXiv Detail & Related papers (2024-12-04T05:16:54Z) - TomoGRAF: A Robust and Generalizable Reconstruction Network for Single-View Computed Tomography [3.1209855614927275]
Traditional analytical/iterative CT reconstruction algorithms require hundreds of angular data samplings.
We develop a novel TomoGRAF framework incorporating the unique X-ray transportation physics to reconstruct high-quality 3D volumes.
arXiv Detail & Related papers (2024-11-12T20:07:59Z) - CoCPF: Coordinate-based Continuous Projection Field for Ill-Posed Inverse Problem in Imaging [78.734927709231]
Sparse-view computed tomography (SVCT) reconstruction aims to acquire CT images based on sparsely-sampled measurements.
Due to ill-posedness, implicit neural representation (INR) techniques may leave considerable holes'' (i.e., unmodeled spaces) in their fields, leading to sub-optimal results.
We propose the Coordinate-based Continuous Projection Field (CoCPF), which aims to build hole-free representation fields for SVCT reconstruction.
arXiv Detail & Related papers (2024-06-21T08:38:30Z) - XCAT-3.0: A Comprehensive Library of Personalized Digital Twins Derived from CT Scans [2.1423779581455182]
This study presents a framework for creating realistic computational phantoms using a suite of automatic segmentation models.
The new formation embodies 140 structures and represents a comprehensive approach to detailed anatomical modeling.
The framework has the potential to advance virtual imaging trials, facilitating reliable evaluations of medical imaging technologies.
arXiv Detail & Related papers (2024-05-18T01:09:02Z) - Multi-View Vertebra Localization and Identification from CT Images [57.56509107412658]
We propose a multi-view vertebra localization and identification from CT images.
We convert the 3D problem into a 2D localization and identification task on different views.
Our method can learn the multi-view global information naturally.
arXiv Detail & Related papers (2023-07-24T14:43:07Z) - Transformers for CT Reconstruction From Monoplanar and Biplanar
Radiographs [0.11219061154635457]
We tackle the problem of reconstructing CT images from biplanar x-rays only.
X-rays are widely available and even if the CT reconstructed from these radiographs is not a replacement of a complete CT in the diagnostic setting, it might serve to spare the patients from radiation.
We propose a novel method based on the transformer architecture, by framing the underlying task as a language translation problem.
arXiv Detail & Related papers (2023-05-11T16:43:39Z) - Geometry-Aware Attenuation Learning for Sparse-View CBCT Reconstruction [53.93674177236367]
Cone Beam Computed Tomography (CBCT) plays a vital role in clinical imaging.
Traditional methods typically require hundreds of 2D X-ray projections to reconstruct a high-quality 3D CBCT image.
This has led to a growing interest in sparse-view CBCT reconstruction to reduce radiation doses.
We introduce a novel geometry-aware encoder-decoder framework to solve this problem.
arXiv Detail & Related papers (2023-03-26T14:38:42Z) - Perspective Projection-Based 3D CT Reconstruction from Biplanar X-rays [32.98966469644061]
We propose PerX2CT, a novel CT reconstruction framework from X-ray.
Our proposed method provides a different combination of features for each coordinate which implicitly allows the model to obtain information about the 3D location.
arXiv Detail & Related papers (2023-03-09T14:45:25Z) - MedNeRF: Medical Neural Radiance Fields for Reconstructing 3D-aware
CT-Projections from a Single X-ray [14.10611608681131]
Excessive ionising radiation can lead to deterministic and harmful effects on the body.
This paper proposes a Deep Learning model that learns to reconstruct CT projections from a few or even a single-view X-ray.
arXiv Detail & Related papers (2022-02-02T13:25:23Z) - XraySyn: Realistic View Synthesis From a Single Radiograph Through CT
Priors [118.27130593216096]
A radiograph visualizes the internal anatomy of a patient through the use of X-ray, which projects 3D information onto a 2D plane.
To the best of our knowledge, this is the first work on radiograph view synthesis.
We show that by gaining an understanding of radiography in 3D space, our method can be applied to radiograph bone extraction and suppression without groundtruth bone labels.
arXiv Detail & Related papers (2020-12-04T05:08:53Z) - Tattoo tomography: Freehand 3D photoacoustic image reconstruction with
an optical pattern [49.240017254888336]
Photoacoustic tomography (PAT) is a novel imaging technique that can resolve both morphological and functional tissue properties.
A current drawback is the limited field-of-view provided by the conventionally applied 2D probes.
We present a novel approach to 3D reconstruction of PAT data that does not require an external tracking system.
arXiv Detail & Related papers (2020-11-10T09:27:56Z) - A Learning-based Method for Online Adjustment of C-arm Cone-Beam CT
Source Trajectories for Artifact Avoidance [47.345403652324514]
The reconstruction quality attainable with commercial CBCT devices is insufficient due to metal artifacts in the presence of pedicle screws.
We propose to adjust the C-arm CBCT source trajectory during the scan to optimize reconstruction quality with respect to a certain task.
We demonstrate that convolutional neural networks trained on realistically simulated data are capable of predicting quality metrics that enable scene-specific adjustments of the CBCT source trajectory.
arXiv Detail & Related papers (2020-08-14T09:23:50Z)
This list is automatically generated from the titles and abstracts of the papers in this site.
This site does not guarantee the quality of this site (including all information) and is not responsible for any consequences.