3D Freehand Ultrasound using Visual Inertial and Deep Inertial Odometry for Measuring Patellar Tracking
- URL: http://arxiv.org/abs/2404.15847v1
- Date: Wed, 24 Apr 2024 12:52:43 GMT
- Title: 3D Freehand Ultrasound using Visual Inertial and Deep Inertial Odometry for Measuring Patellar Tracking
- Authors: Russell Buchanan, S. Jack Tu, Marco Camurri, Stephen J. Mellon, Maurice Fallon,
- Abstract summary: Patellofemoral joint (PFJ) issues affect one in four people, with 20% experiencing chronic knee pain despite treatment.
Traditional imaging methods like CT and MRI face challenges, including cost and metal artefacts.
A new system to monitor joint motion could significantly improve understanding of PFJ dynamics.
- Score: 4.252549987351643
- License: http://arxiv.org/licenses/nonexclusive-distrib/1.0/
- Abstract: Patellofemoral joint (PFJ) issues affect one in four people, with 20% experiencing chronic knee pain despite treatment. Poor outcomes and pain after knee replacement surgery are often linked to patellar mal-tracking. Traditional imaging methods like CT and MRI face challenges, including cost and metal artefacts, and there's currently no ideal way to observe joint motion without issues such as soft tissue artefacts or radiation exposure. A new system to monitor joint motion could significantly improve understanding of PFJ dynamics, aiding in better patient care and outcomes. Combining 2D ultrasound with motion tracking for 3D reconstruction of the joint using semantic segmentation and position registration can be a solution. However, the need for expensive external infrastructure to estimate the trajectories of the scanner remains the main limitation to implementing 3D bone reconstruction from handheld ultrasound scanning clinically. We proposed the Visual-Inertial Odometry (VIO) and the deep learning-based inertial-only odometry methods as alternatives to motion capture for tracking a handheld ultrasound scanner. The 3D reconstruction generated by these methods has demonstrated potential for assessing the PFJ and for further measurements from free-hand ultrasound scans. The results show that the VIO method performs as well as the motion capture method, with average reconstruction errors of 1.25 mm and 1.21 mm, respectively. The VIO method is the first infrastructure-free method for 3D reconstruction of bone from wireless handheld ultrasound scanning with an accuracy comparable to methods that require external infrastructure.
Related papers
- DG-PPU: Dynamical Graphs based Post-processing of Point Clouds extracted from Knee Ultrasounds [0.6790764754753309]
Patients undergoing total knee anterior (TKA) often experience non-specific knee pain, arising from abnormal patellofemoral joint (PFJ) instability.
Tracking PFJ motion is challenging since static imaging modalities like CT and MRI are limited by field of view and metal artefact interference.
We aim to achieve accurate visualisation of patellar tracking and PFJ motion, using 3D registration of point clouds extracted from ultrasound scans.
arXiv Detail & Related papers (2024-11-12T14:04:42Z) - Seamless Augmented Reality Integration in Arthroscopy: A Pipeline for Articular Reconstruction and Guidance [4.8046407905667206]
arthroscopy is a minimally invasive surgical procedure used to diagnose and treat joint problems.
The arthroscope's restricted field of view and lack of depth perception pose challenges in navigating complex articular structures.
We present a robust pipeline that incorporates simultaneous localization and mapping, depth estimation, and 3D Gaussian splatting.
Our solution offers AR assistance for articular notch measurement and annotation anchoring in a human-in-the-loop manner.
arXiv Detail & Related papers (2024-10-01T04:15:49Z) - MotionTTT: 2D Test-Time-Training Motion Estimation for 3D Motion Corrected MRI [24.048132427816704]
We propose a deep learning-based test-time-training method for accurate motion estimation.
We show that our method can provably reconstruct motion parameters for a simple signal and neural network model.
arXiv Detail & Related papers (2024-09-14T08:51:33Z) - 3D Vessel Reconstruction from Sparse-View Dynamic DSA Images via Vessel Probability Guided Attenuation Learning [79.60829508459753]
Current commercial Digital Subtraction Angiography (DSA) systems typically demand hundreds of scanning views to perform reconstruction.
The dynamic blood flow and insufficient input of sparse-view DSA images present significant challenges to the 3D vessel reconstruction task.
We propose to use a time-agnostic vessel probability field to solve this problem effectively.
arXiv Detail & Related papers (2024-05-17T11:23:33Z) - AiAReSeg: Catheter Detection and Segmentation in Interventional
Ultrasound using Transformers [75.20925220246689]
endovascular surgeries are performed using the golden standard of Fluoroscopy, which uses ionising radiation to visualise catheters and vasculature.
This work proposes a solution using an adaptation of a state-of-the-art machine learning transformer architecture to detect and segment catheters in axial interventional Ultrasound image sequences.
arXiv Detail & Related papers (2023-09-25T19:34:12Z) - Two-and-a-half Order Score-based Model for Solving 3D Ill-posed Inverse
Problems [7.074380879971194]
We propose a novel two-and-a-half order score-based model (TOSM) for 3D volumetric reconstruction.
During the training phase, our TOSM learns data distributions in 2D space, which reduces the complexity of training.
In the reconstruction phase, the TOSM updates the data distribution in 3D space, utilizing complementary scores along three directions.
arXiv Detail & Related papers (2023-08-16T17:07:40Z) - Deep learning network to correct axial and coronal eye motion in 3D OCT
retinal imaging [65.47834983591957]
We propose deep learning based neural networks to correct axial and coronal motion artifacts in OCT based on a single scan.
The experimental result shows that the proposed method can effectively correct motion artifacts and achieve smaller error than other methods.
arXiv Detail & Related papers (2023-05-27T03:55:19Z) - Automatic Diagnosis of Carotid Atherosclerosis Using a Portable Freehand
3D Ultrasound Imaging System [18.73291257371106]
A total of 127 3D carotid artery scans were acquired using a portable 3D US system.
A U-Net segmentation network was applied to extract the carotid artery on 2D transverse frame.
A novel 3D reconstruction algorithm using fast dot projection (FDP) method with position regularization was proposed to reconstruct the carotid artery volume.
arXiv Detail & Related papers (2023-01-08T17:35:36Z) - Towards Autonomous Atlas-based Ultrasound Acquisitions in Presence of
Articulated Motion [48.52403516006036]
This paper proposes a vision-based approach allowing autonomous robotic US limb scanning.
To this end, an atlas MRI template of a human arm with annotated vascular structures is used to generate trajectories.
In all cases, the system can successfully acquire the planned vascular structure on volunteers' limbs.
arXiv Detail & Related papers (2022-08-10T15:39:20Z) - Tattoo tomography: Freehand 3D photoacoustic image reconstruction with
an optical pattern [49.240017254888336]
Photoacoustic tomography (PAT) is a novel imaging technique that can resolve both morphological and functional tissue properties.
A current drawback is the limited field-of-view provided by the conventionally applied 2D probes.
We present a novel approach to 3D reconstruction of PAT data that does not require an external tracking system.
arXiv Detail & Related papers (2020-11-10T09:27:56Z) - A Novel Approach for Correcting Multiple Discrete Rigid In-Plane Motions
Artefacts in MRI Scans [63.28835187934139]
We propose a novel method for removing motion artefacts using a deep neural network with two input branches.
The proposed method can be applied to artefacts generated by multiple movements of the patient.
arXiv Detail & Related papers (2020-06-24T15:25:11Z)
This list is automatically generated from the titles and abstracts of the papers in this site.
This site does not guarantee the quality of this site (including all information) and is not responsible for any consequences.