Direct On-Wafer Measurements of Noise Parameters in C- and X-bands at $T=4$ K
- URL: http://arxiv.org/abs/2605.17073v1
- Date: Sat, 16 May 2026 16:43:00 GMT
- Title: Direct On-Wafer Measurements of Noise Parameters in C- and X-bands at $T=4$ K
- Abstract summary: This paper describes the setup and the results of the direct on-wafer measurements of a FET noise parameters obtained with a source-pull method.<n>Resulting noise temperature values are compared against those obtained using independent and alternative measurement techniques.
- Score: 0.0
- License: http://arxiv.org/licenses/nonexclusive-distrib/1.0/
- Abstract: This paper describes the setup and the results of the direct on-wafer measurements of a FET noise parameters obtained with a source-pull method at temperatures down to T=4K and in the 5-12 GHz frequency range. The setup consists of a cryostat with wafer probes, two reflectometers, a programmable impedance generator, wideband isolators and bias tees and low noise preamplifier, all cooled to cryogenic temperatures, allowing to perform a full vector error-corrected wafer-level measurements of the discrete transistors and amplifier dies. The setup and its calibration procedure are designed in a such way that allows simultaneous calibration, S-parameters, noise parameters and I-V curve measurements of several FETs all in one cooldown. Using the described setup we perform first measurements of 14nm FinFETs and also measure noise parameters of an LNA based on these FETs. Resulting noise temperature values are compared against those obtained using independent and alternative measurement techniques.
Related papers
- Traceable In Situ Microwave Power Measurement at the Cryogenic Device Plane in a Dilution Refrigerator [32.63669289843474]
Accurate knowledge of the microwave power delivered to a cryogenic device under test is essential for the characterization and operation of superconducting quantum circuits.<n>This paper presents an in situ measurement method for RF power at the cryogenic device plane.
arXiv Detail & Related papers (2026-07-14T13:18:33Z) - Measurement and Calibration Approaches for Full Two-Port Scattering Parameters at mK Temperatures [32.73124984242397]
The Istituto Nazionale di Ricerca Metrologica (INRiM, Italy), exploits the Short-Open-Load-Reciprocal technique.<n>The system operates at temperatures down to the mK range, in the band 4-12 GHz in coaxial line.
arXiv Detail & Related papers (2025-05-26T12:45:30Z) - Quantifying Jitter Transfer for Differential Measurement: Enhancing Security of Oscillator-Based TRNGs [1.104960878651584]
This paper describes a way to improve the reliability of the measurement of the statistical parameters of the phase noise in a TRNG.
It is necessary to guarantee that the entropy rate is within the bounds prescribed by standards or security specifications.
We show the relevance of our method with simulations and experiments with hardware implementations.
arXiv Detail & Related papers (2024-10-10T17:57:03Z) - Overcoming the Thermal-Noise Limit of Microwave Measurements by Pre-cooling with an Active Cold Load [0.34530027457862006]
We introduce a method, which we here name active pre-cooling'' (APC), for removing, just prior to performing a measurement, a large fraction of the deleterious thermal photons that would otherwise occupy the electromagnetic modes of a microwave cavity.<n>We report a room-temperature bench-top demonstration of the method, where this load takes the form of the input of a commercial low-noise amplifier (LNA)
arXiv Detail & Related papers (2024-08-09T22:43:29Z) - Development of KI-TWPAs for the DARTWARS project [45.045423476064414]
Noise at the quantum limit over a broad bandwidth is a fundamental requirement for future cryogenic experiments.
We develop Kinetic Inductance Travelling-Wave Parametric Amplifiers (KI-TWPAs) for low temperature detectors and qubit read-out.
KI-TWPAs are typically operated in a threewave mixing (3WM) mode and are characterised by a high gain, a high saturation power, a large amplification bandwidth and nearly quantum limited noise performance.
arXiv Detail & Related papers (2024-02-19T17:18:25Z) - Fast high-fidelity charge readout by operating the cavity-embedded
Cooper pair transistor in the Kerr bistable regime [55.41644538483948]
We demonstrate single-shot resolution between two charge states that are $0.09e$ apart.
The measurement is performed with 94$%$ fidelity in a duration of 3 $mu$s.
arXiv Detail & Related papers (2022-12-31T03:44:10Z) - Probing flux and charge noise with macroscopic resonant tunneling [45.36850110238202]
We measure rates of incoherent tunneling from the lowest energy state in the initial well to the ground.
We develop a theoretical model that allows us to extract information about flux and charge noise within one experimental setup.
arXiv Detail & Related papers (2022-10-04T16:15:34Z) - Measurement of the Low-temperature Loss Tangent of High-resistivity
Silicon with a High Q-factor Superconducting Resonator [58.720142291102135]
We present the direct loss tangent measurement of a high-resist intrinsicivity (100) silicon wafer in the temperature range from 70 mK to 1 K.
The measurement was performed using a technique that takes advantage of a high quality factor superconducting niobium resonator.
arXiv Detail & Related papers (2021-08-19T20:13:07Z) - Cryogenic single-port calibration for superconducting microwave
resonator measurements [0.0]
In this paper, we demonstrate a data-based, single-port calibration using commercial microwave standards and a vector network analyzer (VNA)
We cross reference our data-based, single-port calibration and reflection measurement with over-coupled 2D- and 3D-resonators against well established two-port techniques corroborating the validity of our method.
arXiv Detail & Related papers (2021-03-02T06:24:51Z) - Adiabatic Sensing Technique for Optimal Temperature Estimation using
Trapped Ions [64.31011847952006]
We propose an adiabatic method for optimal phonon temperature estimation using trapped ions.
The relevant information of the phonon thermal distributions can be transferred to the collective spin-degree of freedom.
We show that each of the thermal state probabilities is adiabatically mapped onto the respective collective spin-excitation configuration.
arXiv Detail & Related papers (2020-12-16T12:58:08Z) - Noise performance & thermalization of single electron transistors using
quantum fluids [0.0]
We report on low-temperature noise measurements of a single electron transistor immersed in superfluid $4$He.
The device acts as a charge sensitive electrometer able to detect the fluctuations of charged defects in close proximity to the SET.
We find that the presence of superfluid $4$He can strongly suppress the switching rate of the defect by cooling the surrounding phonon bath.
arXiv Detail & Related papers (2020-10-13T20:19:31Z) - Real-time estimation of the optically detected magnetic resonance shift
in diamond quantum thermometry [47.50219326456544]
We investigate the real-time estimation protocols for the frequency shift of optically detected magnetic resonance (ODMR) of nitrogen-vacancy centers in nanodiamonds (NDs)
Efficiently integrating multipoint ODMR measurements and ND particle tracking into fluorescence microscopy has recently demonstrated stable monitoring of the temperature inside living animals.
arXiv Detail & Related papers (2020-06-12T01:44:35Z)
This list is automatically generated from the titles and abstracts of the papers in this site.
This site does not guarantee the quality of this site (including all information) and is not responsible for any consequences.