Picometer control of a levitating milligram gravity sensor
- URL: http://arxiv.org/abs/2605.28479v1
- Date: Wed, 27 May 2026 13:39:09 GMT
- Title: Picometer control of a levitating milligram gravity sensor
- Abstract summary: We present linear feedback cooling of a magnetically levitated gravity sensor to below 2 picometer amplitude and below 10 millikelvin mode temperature.<n>We discuss future improvements on the setup which may enable quantum ground state cooling on a magnetically levitated particle.
- Score: 0.0
- License: http://creativecommons.org/licenses/by/4.0/
- Abstract: Due to their exceptional isolation from the environment, magnetically levitated particles are explored as extremely sensitive mechanical sensors. For future gravity experiments on quantum superpositions, such systems need to be cooled close to their ground state. To demonstrate the combination of state of the art vibration isolation, milligram levitated high Q mechanical resonators and position detection with low noise, we present linear feedback cooling of a magnetically levitated gravity sensor to below 2 picometer amplitude and below 10 millikelvin mode temperature for two translational modes (the x- and y-mode) simultaneously. The sensor is a levitating permanent magnet in a type I superconducting trap, where its six resonance frequencies are measured with a superconducting coil coupled to a DC SQUID. This signal is measured with a lock-in amplifier and a feedback signal is sent to a piezoelectric actuator, allowing the cooling of resonant modes at 50.6 and 68.0 Hz simultaneously. These two translational modes have Q factors of $3.8 \cdot 10^6$ and $5.5 \cdot 10^6$ respectively. The experiment is mounted inside a dry dilution refrigerator where it is vibrationally attenuated with 110-130 dB at these frequencies. In this work, we discuss future improvements on the setup which may enable quantum ground state cooling on a magnetically levitated particle, that has previously been shown to be a gravitational sensor.
Related papers
- Bose condensation and Bogoliubov excitation in resonator-embedded superconducting qubit network [53.72731614116211]
Superconducting qubit networks (SQNs) embedded in a low-dissipative resonator are a promising device.<n>A quantum ac Stark effect provides by coupling between an SQN and microwave photons of a resonator, leads to a strong nonlinear interaction between photons.
arXiv Detail & Related papers (2026-01-21T15:43:43Z) - Remote sensing of a levitated superconductor with a flux-tunable microwave cavity [0.1662044453232128]
A superconducting quantum interference device is embedded in a microwave resonator and coupled via a pick-up loop to a magnetically-levitated superconducting sphere.
The motion of the sphere in the magnetic trap induces a frequency shift in the SQUID-cavity system.
The measured displacement sensitivity of $10-7, mathrmm / sqrtmathrmHz$, defines a path towards ground-state cooling of levitated particles with Planck-scale masses at millikelvin environment temperatures.
arXiv Detail & Related papers (2024-01-16T22:08:31Z) - Ferrimagnetic Oscillator Magnetometer [0.0]
The device exhibits a fixed, calibration-free response governed by the electronmagnetic gyro ratio.
The device achieves a minimum sensitivity of 100 fT/$sqrttextHz$ to AC magnetic fields of unknown phase.
arXiv Detail & Related papers (2023-05-31T15:21:57Z) - High-Q magnetic levitation and control of superconducting microspheres
at millikelvin temperatures [0.45690798330675886]
We report the levitation of a superconducting lead-tin sphere with 100 micrometer diameter (corresponding to a mass of 5.6 micrograms) in a static magnetic trap.
The center-of-mass motion of the sphere is monitored using a dc superconducting quantum interference device.
arXiv Detail & Related papers (2022-11-11T15:54:29Z) - Superconducting microsphere magnetically levitated in an anharmonic
potential with integrated magnetic readout [0.0]
We levitate a 700ng $sim 1017$amu superconducting microsphere in a magnetic chip trap.
We measure the particle's center-of-mass motion using a DC-SQUID magnetometer.
We characterize motional-amplitude-dependent frequency shifts, which arise from trap anharmonicities.
arXiv Detail & Related papers (2022-10-24T17:59:56Z) - Measuring the magnon-photon coupling in shaped ferromagnets: tuning of
the resonance frequency [50.591267188664666]
cavity photons and ferromagnetic spins excitations can exchange information coherently in hybrid architectures.
Speed enhancement is usually achieved by optimizing the geometry of the electromagnetic cavity.
We show that the geometry of the ferromagnet plays also an important role, by setting the fundamental frequency of the magnonic resonator.
arXiv Detail & Related papers (2022-07-08T11:28:31Z) - A background-free optically levitated charge sensor [50.591267188664666]
We introduce a new technique to model and eliminate dipole moment interactions limiting the performance of sensors employing levitated objects.
As a demonstration, this is applied to the search for unknown charges of a magnitude much below that of an electron.
As a by-product of the technique, the electromagnetic properties of the levitated objects can also be measured on an individual basis.
arXiv Detail & Related papers (2021-12-20T08:16:28Z) - Demonstrating levitation within a microwave cavity [0.0]
We report the first successful experiments with a levitated millimeter-scale neodymium magnet within a centimeter-scale superconducting aluminum coaxial quarter-wave stub cavity.
Resonance spectra are collected via a vector network analyzer (VNA) between temperatures of 5 K and 50 mK revealing movement of the magnet inside of the cavity.
arXiv Detail & Related papers (2021-01-05T01:42:09Z) - Photon Condensation and Enhanced Magnetism in Cavity QED [68.8204255655161]
A system of magnetic molecules coupled to microwave cavities undergoes the equilibrium superradiant phase transition.
The effect of the coupling is first illustrated by the vacuum-induced ferromagnetic order in a quantum Ising model.
A transmission experiment is shown to resolve the transition, measuring the quantum electrodynamical control of magnetism.
arXiv Detail & Related papers (2020-11-07T11:18:24Z) - Ferromagnetic Gyroscopes for Tests of Fundamental Physics [49.853792068336034]
A ferromagnetic gyroscope (FG) is a ferromagnet whose angular momentum is dominated by electron spin polarization and that will precess under the action of an external torque.
We model and analyze FG dynamics and sensitivity, focusing on practical schemes for experimental realization.
arXiv Detail & Related papers (2020-10-17T07:13:50Z) - High-Frequency Gravitational-Wave Detection Using a Chiral Resonant
Mechanical Element and a Short Unstable Optical Cavity [59.66860395002946]
We suggest the measurement of the twist of a chiral mechanical element induced by a gravitational wave.
The induced twist rotates a flat optical mirror on top of this chiral element, leading to the deflection of an incident laser beam.
We estimate a gravitational wave strain sensitivity between 10-21/sqrtHz and 10-23/sqrtHz at around 10 kHz frequency.
arXiv Detail & Related papers (2020-07-15T20:09:43Z)
This list is automatically generated from the titles and abstracts of the papers in this site.
This site does not guarantee the quality of this site (including all information) and is not responsible for any consequences.