Estimating IF shifts based on SU(1,1) interferometer
- URL: http://arxiv.org/abs/2307.00291v1
- Date: Sat, 1 Jul 2023 10:16:35 GMT
- Title: Estimating IF shifts based on SU(1,1) interferometer
- Authors: Chen Yuetao, Chen Gaiqing, Luo MengMeng, Chang Shoukang and Gao
Shaoyan
- Abstract summary: We propose a theoretical scheme to investigate the IF shifts and incident angle sensitivity by introducing SPR sensor into the SU (1,1) interferometer.
By injecting two coherent states in the SU (1,1) interferometer, we obtain the sensitivity of the IF shifts and incident angle based on the homodyne detection.
Our results can be helpful in the development of more precise quantum-based sensors for studying light-matter interactions.
- Score: 0.0
- License: http://arxiv.org/licenses/nonexclusive-distrib/1.0/
- Abstract: IF (Imbert--Fedorov) shifts which refers to a transverse micro-displacement
occurs at the interface between two media. The estimation of such
micro-displacement enables a deeper understanding of light-matter interactions.
In this paper, we propose a theoretical scheme to investigate the IF shifts and
incident angle sensitivity by introducing SPR sensor into the SU(1,1)
interferometer. By injecting two coherent states in the SU(1,1) interferometer,
we obtain the sensitivity of the IF shifts and incident angle based on the
homodyne detection. Our results demonstrate that it is possible to get the
maximal IF shift and the optimal IF shifts sensitivity simultaneously.
Meanwhile, the orbit angular momentum carried by Laguerre-Gauss (LG) beam is
unfavorable for improving the IF shift sensitivity. Furthermore, we have
investigated the sensitivity of the incident angle in our scheme and found that
it is capable of surpassing the sensitivity limit of $(6\times
10^{-6}){{}^\circ}$. This allows us to achieve a more precise IF shifts
sensitivity than the traditional weak measurement method used for IF shift
detection, which typically has a rotation precision limit of 0.04${{}^\circ}$
[Journal of Optics, 19(10), 105611]. More importantly, both the sensitivity of
IF shifts and incident angle can breakthrough the (shot noise limit) SNL, even
approaching the Cram\'{e}r-Rao bound (QCRB) at the incident angle $\theta
=43.6208{{}^\circ}$ and $\theta =43.6407{{}^\circ}$. We also discover that
increasing the coherent amplitude is beneficial for improving the sensitivity
of both the IF shifts and incident angle. Our findings shall offer a novel
scheme for measuring micro-displacement in SPR sensor. These results can be
helpful in the development of more precise quantum-based sensors for studying
light-matter interactions.
Related papers
- Unambiguous measurement in an unshielded microscale magnetometer with sensitivity below 1 pT/rHz [0.0]
We describe how Hilbert-demodulated optical magnetometry can be realised on cold atom sensors.
We measure a test field to be $ 86.0121261(4) ; mathrmmu T$ in a single shot, achieving dc sensitivity of 380 fT in a duration of 1000 ms.
arXiv Detail & Related papers (2023-09-21T06:56:18Z) - Multiparameter quantum sensing and magnetic communications with a hybrid dc and rf optically pumped magnetometer [41.94295877935867]
We introduce and demonstrate a hybrid optically pumped magnetometer (HOPM) that simultaneously measures one dc field component and one RF field component quadrature.
The HOPM achieves sub-pT/$sqrtmathrmHz$ sensitivity for both dc and RF fields, and is limited in sensitivity by spin projection noise at low frequencies and by photon shot noise at high frequencies.
arXiv Detail & Related papers (2023-08-27T22:17:21Z) - Feasibility of a trapped atom interferometer with accelerating optical traps [0.0]
We propose a setup for high-bandwidth applications, with improved overall sensitivity.
We find that accelerations of up to $103$-$105$ m/s$2$ can be achieved using acousto-optic deflectors (AODs)
In the limit of appropriate beam and optics stabilization, sensitivities approaching 10-14$ (m/s$2$)/$sqrtrm Hz$ may be achievable at 1 Hz.
arXiv Detail & Related papers (2023-08-23T16:46:16Z) - First-step experiment in developing optical-spring quantum locking for
DECIGO: sensitivity optimization for simulated quantum noise by completing
the square [1.7030294562102306]
DECIGO has 1,000-km-long arm cavities mainly to detect primordial gravitational waves (PGW) at lower around 0.1 Hz.
We experimentally verify one key element of the optical-spring quantum locking: sensitivity optimization by completing the square of multiple detector outputs.
arXiv Detail & Related papers (2022-11-23T03:32:10Z) - Sensitivity Comparison of Two-photon vs Three-photon Rydberg
Electrometry [45.82374977939355]
We model the 4-level and 5-level atomic system and compare how the transmission of the probe changes with different powers of the lasers used and strengths of the RF field.
We find that the three-photon system boasts much narrower line widths compared to the conventional two-photon EIT.
In addition to this, we calculate the expected sensitivity for the two-photon Rydberg sensor and find that the best achievable sensitivity is over an order of magnitude better than the current measured values of 5 uV/m/Hz.
arXiv Detail & Related papers (2022-11-21T20:46:24Z) - DC Quantum Magnetometry Below the Ramsey Limit [68.8204255655161]
We demonstrate quantum sensing of dc magnetic fields that exceeds the sensitivity of conventional $Tast$-limited dc magnetometry by more than an order of magnitude.
We used nitrogen-vacancy centers in a diamond rotating at periods comparable to the spin coherence time, and characterize the dependence of magnetic sensitivity on measurement time and rotation speed.
arXiv Detail & Related papers (2022-03-27T07:32:53Z) - Investigation and comparison of measurement schemes in the low frequency
biosensing regime using solid-state defect centers [58.720142291102135]
Solid state defects in diamond make promising quantum sensors with high sensitivity andtemporal resolution.
Inhomogeneous broadening and drive amplitude variations have differing impacts on the sensitivity depending on the sensing scheme used.
We numerically investigate and compare the predicted sensitivity of schemes based on continuous-wave (CW) optically detected magnetic resonance (ODMR) spectroscopy, pi-pulse ODMR and Ramsey interferometry.
arXiv Detail & Related papers (2021-09-27T13:05:23Z) - Squeezed-light enhancement and backaction evasion in a high sensitivity
optically pumped magnetometer [0.0]
We study the effect of optical polarization squeezing on the performance of a sensitive, quantum-noise-limited optically pumped magnetometer.
We provide a model for the quantum noise dynamics of the BB magnetometer, including spin projection noise, probe polarization noise, and measurement backaction effects.
arXiv Detail & Related papers (2021-08-03T14:07:58Z) - Fundamental Sensitivity Bounds for Quantum Enhanced Optical Resonance
Sensors Based on Transmission and Phase Estimation [1.6230648949593154]
We study optical resonance sensors, which detect a change in a parameter of interest through a resonance shift.
We show that the fundamental sensitivity results from an interplay between the QCRB and the transfer function of the system.
We also study the effect of losses external to the sensor on the degree of quantum enhancement.
arXiv Detail & Related papers (2021-06-14T20:23:12Z) - Spectrally multimode integrated SU(1,1) interferometer [50.591267188664666]
The presented interferometer includes a polarization converter between two photon sources and utilizes a continuous-wave (CW) pump.
We show that this configuration results in almost perfect destructive interference at the output and supersensitivity regions below the classical limit.
arXiv Detail & Related papers (2020-12-07T14:42:54Z) - High-Frequency Gravitational-Wave Detection Using a Chiral Resonant
Mechanical Element and a Short Unstable Optical Cavity [59.66860395002946]
We suggest the measurement of the twist of a chiral mechanical element induced by a gravitational wave.
The induced twist rotates a flat optical mirror on top of this chiral element, leading to the deflection of an incident laser beam.
We estimate a gravitational wave strain sensitivity between 10-21/sqrtHz and 10-23/sqrtHz at around 10 kHz frequency.
arXiv Detail & Related papers (2020-07-15T20:09:43Z)
This list is automatically generated from the titles and abstracts of the papers in this site.
This site does not guarantee the quality of this site (including all information) and is not responsible for any consequences.