3D-Printed Anisotropic Soft Magnetic Coating for Directional Rolling of a Magnetically Actuated Capsule Robot
- URL: http://arxiv.org/abs/2602.10688v1
- Date: Wed, 11 Feb 2026 09:43:03 GMT
- Title: 3D-Printed Anisotropic Soft Magnetic Coating for Directional Rolling of a Magnetically Actuated Capsule Robot
- Abstract summary: Conventional magnetic capsule robots embed bulky permanent magnets at both ends.<n>We propose a compact, 3D-printed soft capsule robot with a magnetic coating that replaces internal magnets.<n>The compliant silicone-magnetic composite also improves swallowability, even with a slightly larger capsule size.
- Score: 1.833032119491673
- License: http://arxiv.org/licenses/nonexclusive-distrib/1.0/
- Abstract: Capsule robots are promising tools for minimally invasive diagnostics and therapy, with applications from gastrointestinal endoscopy to targeted drug delivery and biopsy sampling. Conventional magnetic capsule robots embed bulky permanent magnets at both ends, reducing the usable cavity by about 10-20 mm and limiting integration of functional modules. We propose a compact, 3D-printed soft capsule robot with a magnetic coating that replaces internal magnets, enabling locomotion via a thin, functional shell while preserving the entire interior cavity as a continuous volume for medical payloads. The compliant silicone-magnetic composite also improves swallowability, even with a slightly larger capsule size. Magnetostatic simulations and experiments confirm that programmed NSSN/SNNS pole distributions provide strong anisotropy and reliable torque generation, enabling stable bidirectional rolling, omnidirectional steering, climbing on 7.5 degree inclines, and traversal of 5 mm protrusions. Rolling motion is sustained when the magnetic field at the capsule reaches at least 0.3 mT, corresponding to an effective actuation depth of 30 mm in our setup. Future work will optimize material composition, coating thickness, and magnetic layouts to enhance force output and durability, while next-generation robotic-arm-based field generators with closed-loop feedback will address nonlinearities and expand maneuverability. Together, these advances aim to transition coating-based capsule robots toward reliable clinical deployment and broaden their applications in minimally invasive diagnostics and therapy.
Related papers
- Programmable magnetic soft robots with controlled locomotion and directional liquid cargo release [0.0]
Magnetically programmable soft elastomers enable shape morphing and locomotion dynamics in small scale soft robots under external magnetic fields.<n>New strategy integrates directional targeted liquid cargo release, shape morphing, and locomotion, which establishes the groundwork for target drug delivery in gastrointestinal tract applications.
arXiv Detail & Related papers (2026-06-19T20:48:02Z) - A tunable feedback-controlled magnetic trap for a magnet in free fall [41.89902918118875]
We propose and demonstrate a novel master proportional-integral-differential magnetic trap (MPIDMT)<n>During the microgravity phase the system stably levitates a ferromagnetic particle against shock accelerations up to 1.5 g and resolves its motion in both a low-field (0.4 g) configuration and in pure free fall.<n>Results represent a key step toward free-fall ferromagnetic magnetometry, the long-sought direct observation of macroscopic Larmor precession, and future space-based experiments.
arXiv Detail & Related papers (2026-05-31T06:56:41Z) - A physics-informed foundation model for quantitative diffusion MRI [46.74037857287099]
A physics-informed generative microstructure network (PIGMENT) learns a universal generative prior to human brain microstructure and adapts it zero-shot to each participant's measured data to recover subject-specific maps.<n>PIGMENT estimates demonstrated strong biological validity, preserving submillimeter cortical microarchitectural patterns and early-childhood white matter developmental trajectories from 10-fold accelerated scans.<n>These results establish PIGMENT as a physics-informed foundation model that extends quantitative diffusion MRI into regimes traditionally too sparse, heterogeneous, or clinically constrained for reliable analysis.
arXiv Detail & Related papers (2026-05-29T07:26:35Z) - Muscle-inspired magnetic actuators that push, pull, crawl, and grasp [0.1957338076370071]
Functional magnetic composites capable of large deformation, load bearing, and multifunctional motion are essential for next-generation adaptive soft robots.<n>We present muscle-inspired magnetic actuators (MMA), additively manufactured from a thermoplastic/permanent magnet polyurethane/Nd2Fe14B composite.
arXiv Detail & Related papers (2026-04-20T11:05:27Z) - Levitated Ferromagnetic Torsional Oscillators for High-Precision Magnetometry and Probing Exotic Interactions [0.0]
The device attains a remarkable magnetic sensitivity of $391pm 59, rmfTcdot Hz-1/2$.<n>This capability enables precise detection of weak magnetic fields and provides a novel platform for exploring exotic interactions beyond the Standard Model.
arXiv Detail & Related papers (2026-03-02T17:00:19Z) - A Robotic Testing Platform for Pipelined Discovery of Resilient Soft Actuators [63.07587517846448]
We propose an optimization pipeline enabled by a novel testing robot capable of scanning DEA lifetime.<n>The robot integrates electro-mechanical property measurement, programmable voltage input, and multi-channel testing capacity.<n>Using it, we scanned the lifetime of Elastosil-based linear actuators across parameters including input voltage magnitude, frequency, electrode material concentration, and electrical connection filler.
arXiv Detail & Related papers (2026-02-24T14:41:28Z) - Fluoroscopy-Constrained Magnetic Robot Control via Zernike-Based Field Modeling and Nonlinear MPC [4.093982213892736]
Magnetic actuation enables surgical robots to navigate complex anatomical pathways while reducing tissue trauma and improving surgical precision.<n>This paper presents a control framework that remains accurate and stable under such conditions by combining a nonlinear model predictive control framework.<n> Experimental validation is conducted with two magnetic robots in a 3D-printed fluid workspace and a spine phantom replicating drug delivery in the epidural space.
arXiv Detail & Related papers (2026-02-17T04:50:18Z) - Pitch Angle Control of a Magnetically Actuated Capsule Robot with Nonlinear FEA-based MPC and EKF Multisensory Fusion [0.3694429692322632]
This paper presents a model-based framework for magnetic pitch control of an ingestible capsule robot actuated by a four-coil electromagnetic array.<n>Experiments on a compliant stomach-inspired surface demonstrate robust pitch reorientation from both horizontal and upright configurations.<n>These results establish finite-element-informed MPC with sensor fusion as a scalable strategy for pitch regulation, controlled docking, and future multi-degree-of-freedom capsule locomotion.
arXiv Detail & Related papers (2026-02-11T07:59:52Z) - Moving Beyond Compliance in Soft-Robotic Catheters Through Modularity for Precision Therapies [0.0]
Soft robotic instruments could navigate delicate, tortuous anatomy more safely than rigid tools.<n>Few sensing and therapeutic modules are compact, robust, and adaptable enough to measure, and respond to, subtle physiological cues during intraluminal procedures.<n>We present a 1.47 mm diameter modular soft robotic catheter that integrates sensing, actuation, and therapy while retaining the compliance needed for safe endoluminal navigation.
arXiv Detail & Related papers (2026-01-21T10:11:59Z) - Controllable and Continuous Quantum Phase Transitions in Intrinsic Magnetic Topological Insulator [50.54133633499971]
We study the intrinsic magnetic topological material MnBi2Te4 in which the heavy n-type doping features are strongly suppressed.<n>Based on angle-resolved photoemission spectroscopy, transport measurements, and first-principles calculations, we reveal two magnetism-induced TPTs.<n>Our work paves the way for the realization of intrinsic magnetic topological states in MnBi2Te4 family and provides an ideal platform for achieving controllable and continuous TPTs.
arXiv Detail & Related papers (2025-03-08T03:46:54Z) - Diamagnetic micro-chip traps for levitated nanoparticle entanglement experiments [0.0]
Quantum Gravity Mediated Entanglement (QGEM) protocol offers a novel method to probe the quantumness of gravitational interactions at non-relativistic scales.
We propose using magnetic traps based on micro-fabricated wires to trap nanoparticles for interferometric entanglement experiments.
arXiv Detail & Related papers (2024-11-04T17:48:32Z) - Imaging magnetism evolution of magnetite to megabar pressure range with
quantum sensors in diamond anvil cell [57.91882523720623]
We develop an in-situ magnetic detection technique at megabar pressures with high sensitivity and sub-microscale spatial resolution.
We observe the macroscopic magnetic transition of Fe3O4 in the megabar pressure range from strong ferromagnetism (alpha-Fe3O4) to weak ferromagnetism (beta-Fe3O4) and finally to non-magnetism (gamma-Fe3O4)
The presented method can potentially investigate the spin-orbital coupling and magnetism-superconductivity competition in magnetic systems.
arXiv Detail & Related papers (2023-06-13T15:19:22Z) - Designer Magnetism in High Entropy Oxides [41.74498230885008]
Disorder can have a dominating influence on correlated and quantum materials.
In magnetic systems, spin and exchange disorder can provide access to quantum criticality, frustration, and spin dynamics.
We show that high entropy oxides present an unexplored route to designing quantum materials.
arXiv Detail & Related papers (2021-04-12T15:21:48Z) - A mechanically stable and tunable cryogenic Fabry-Perot microcavity [0.0]
High-finesse, open-geometry microcavities have recently emerged as a versatile tool for enhancing interactions between photons and material systems.
We present the design and characterization of a system that can achieve $sim$16 pm-rms passive mechanical stability between two high-finesse mirrors.
Our results facilitate operation of a tunable, high-finesse cavity within a closed-cycle cryostat, representing an enabling technology for cavity coupling to a variety of solid-state systems.
arXiv Detail & Related papers (2021-03-05T17:32:12Z) - Detection of biological signals from a live mammalian muscle using a
diamond quantum sensor [41.91891973513696]
We show an alternative technique for detecting magnetic fields generated by the current from action potentials in living tissue using nitrogen vacancy centres in diamond.
We show these measurements can be performed in an ordinary, unshielded lab environment and that the signal can be easily recovered by digital signal processing techniques.
arXiv Detail & Related papers (2020-08-03T16:40:44Z) - Optimisation of a diamond nitrogen vacancy centre magnetometer for
sensing of biological signals [44.62475518267084]
We present advances in biomagnetometry using nitrogen vacancy centres in diamond.
We show magnetic field sensitivity of approximately 100 pT/$sqrtHz$ in the DC/low frequency range using a setup designed for biological measurements.
arXiv Detail & Related papers (2020-04-05T18:44:34Z)
This list is automatically generated from the titles and abstracts of the papers in this site.
This site does not guarantee the quality of this site (including all information) and is not responsible for any consequences.