Standardizing Medical Images at Scale for AI
- URL: http://arxiv.org/abs/2603.15980v1
- Date: Mon, 16 Mar 2026 22:51:52 GMT
- Title: Standardizing Medical Images at Scale for AI
- Abstract summary: We present a physics-based data preprocessing framework based on the PhyCV family of algorithms.<n>It standardizes medical images through deterministic transformations derived from optical physics.<n>It improves out-of-distribution breast-cancer classification accuracy from 70.8% to 90.9%, matching or exceeding data-augmentation and domain-generalization approaches.
- Score: 3.26654570054705
- License: http://creativecommons.org/licenses/by-nc-nd/4.0/
- Abstract: Deep learning has achieved remarkable success in medical image analysis, yet its performance remains highly sensitive to the heterogeneity of clinical data. Differences in imaging hardware, staining protocols, and acquisition conditions produce substantial domain shifts that degrade model generalization across institutions. Here we present a physics-based data preprocessing framework based on the PhyCV (Physics-Inspired Computer Vision) family of algorithms, which standardizes medical images through deterministic transformations derived from optical physics. The framework models images as spatially varying optical fields that undergo a virtual diffractive propagation followed by coherent phase detection. This process suppresses non-semantic variability such as color and illumination differences while preserving diagnostically relevant texture and structural features. When applied to histopathological images from the Camelyon17-WILDS benchmark, PhyCV preprocessing improves out-of-distribution breast-cancer classification accuracy from 70.8% (Empirical Risk Minimization baseline) to 90.9%, matching or exceeding data-augmentation and domain-generalization approaches at negligible computational cost. Because the transform is physically interpretable, parameterizable, and differentiable, it can be deployed as a fixed preprocessing stage or integrated into end-to-end learning. These results establish PhyCV as a generalizable data refinery for medical imaging-one that harmonizes heterogeneous datasets through first-principles physics, improving robustness, interpretability, and reproducibility in clinical AI systems.
Related papers
- Layout-Guided Controllable Pathology Image Generation with In-Context Diffusion Transformers [57.54843029965778]
Controllable pathology image synthesis requires reliable regulation of spatial layout, tissue morphology, and semantic detail.<n>We propose In-Context Diffusion Transformer (IC-DiT), a layout-aware generative model that incorporates spatial layouts, textual descriptions, and visual embeddings into a unified diffusion transformer.<n>IC-DiT achieves higher fidelity, stronger spatial controllability, and better diagnostic consistency than existing methods.
arXiv Detail & Related papers (2026-03-11T06:14:11Z) - Plasticine: A Traceable Diffusion Model for Medical Image Translation [79.39689106440389]
We propose Plasticine, to the best of our knowledge, the first end-to-end image-to-image translation framework explicitly designed with traceability as a core objective.<n>Our method combines intensity translation and spatial transformation within a denoising diffusion framework.<n>This design enables the generation of synthetic images with interpretable intensity transitions and spatially coherent deformations, supporting pixel-wise traceability throughout the translation process.
arXiv Detail & Related papers (2025-12-20T18:01:57Z) - DeepGI: Explainable Deep Learning for Gastrointestinal Image Classification [0.0]
The study confronts common endoscopic challenges such as variable lighting, fluctuating camera angles, and frequent imaging artifacts.<n>The best performing models, VGG16 and MobileNetV2, each achieved a test accuracy of 96.5%.<n>The approach includes explainable AI via Grad-CAM visualization, enabling identification of image regions most influential to model predictions.
arXiv Detail & Related papers (2025-11-26T22:35:57Z) - Accelerating 3D Photoacoustic Computed Tomography with End-to-End Physics-Aware Neural Operators [74.65171736966131]
Photoacoustic computed tomography (PACT) combines optical contrast with ultrasonic resolution, achieving deep-tissue imaging beyond the optical diffusion limit.<n>Current implementations require dense transducer arrays and prolonged acquisition times, limiting clinical translation.<n>We introduce Pano, an end-to-end physics-aware model that directly learns the inverse acoustic mapping from sensor measurements to volumetric reconstructions.
arXiv Detail & Related papers (2025-09-11T23:12:55Z) - Disease Classification and Impact of Pretrained Deep Convolution Neural Networks on Diverse Medical Imaging Datasets across Imaging Modalities [0.0]
This paper investigates the intricacies of using pretrained deep convolutional neural networks with transfer learning across diverse medical imaging datasets.
It shows that the use of pretrained models as fixed feature extractors yields poor performance irrespective of the datasets.
It is also found that deeper and more complex architectures did not necessarily result in the best performance.
arXiv Detail & Related papers (2024-08-30T04:51:19Z) - Understanding differences in applying DETR to natural and medical images [16.200340490559338]
Transformer-based detectors have shown success in computer vision tasks with natural images.<n>Medical imaging data presents unique challenges such as extremely large image sizes, fewer and smaller regions of interest, and object classes which can be differentiated only through subtle differences.<n>This study evaluates the applicability of these transformer-based design choices when applied to a screening mammography dataset.
arXiv Detail & Related papers (2024-05-27T22:06:42Z) - Adapting Visual-Language Models for Generalizable Anomaly Detection in Medical Images [68.42215385041114]
This paper introduces a novel lightweight multi-level adaptation and comparison framework to repurpose the CLIP model for medical anomaly detection.
Our approach integrates multiple residual adapters into the pre-trained visual encoder, enabling a stepwise enhancement of visual features across different levels.
Our experiments on medical anomaly detection benchmarks demonstrate that our method significantly surpasses current state-of-the-art models.
arXiv Detail & Related papers (2024-03-19T09:28:19Z) - On Sensitivity and Robustness of Normalization Schemes to Input
Distribution Shifts in Automatic MR Image Diagnosis [58.634791552376235]
Deep Learning (DL) models have achieved state-of-the-art performance in diagnosing multiple diseases using reconstructed images as input.
DL models are sensitive to varying artifacts as it leads to changes in the input data distribution between the training and testing phases.
We propose to use other normalization techniques, such as Group Normalization and Layer Normalization, to inject robustness into model performance against varying image artifacts.
arXiv Detail & Related papers (2023-06-23T03:09:03Z) - Magnification Invariant Medical Image Analysis: A Comparison of
Convolutional Networks, Vision Transformers, and Token Mixers [2.3859625728972484]
Convolution Neural Networks (CNNs) are widely used in medical image analysis.
Their performance degrade when the magnification of testing images differ from the training images.
This study aims to evaluate the robustness of various deep learning architectures.
arXiv Detail & Related papers (2023-02-22T16:44:41Z) - Negligible effect of brain MRI data preprocessing for tumor segmentation [36.89606202543839]
We conduct experiments on three publicly available datasets and evaluate the effect of different preprocessing steps in deep neural networks.
Our results demonstrate that most popular standardization steps add no value to the network performance.
We suggest that image intensity normalization approaches do not contribute to model accuracy because of the reduction of signal variance with image standardization.
arXiv Detail & Related papers (2022-04-11T17:29:36Z) - Deep learning-based bias transfer for overcoming laboratory differences
of microscopic images [0.0]
We evaluate, compare, and improve existing generative model architectures to overcome domain shifts for immunofluorescence (IF) and Hematoxylin and Eosin (H&E) stained microscopy images.
Adapting the bias of the samples significantly improved the pixel-level segmentation for human kidney glomeruli and podocytes and improved the classification accuracy for human prostate biopsies by up to 14%.
arXiv Detail & Related papers (2021-05-25T09:02:30Z) - A parameter refinement method for Ptychography based on Deep Learning
concepts [55.41644538483948]
coarse parametrisation in propagation distance, position errors and partial coherence frequently menaces the experiment viability.
A modern Deep Learning framework is used to correct autonomously the setup incoherences, thus improving the quality of a ptychography reconstruction.
We tested our system on both synthetic datasets and also on real data acquired at the TwinMic beamline of the Elettra synchrotron facility.
arXiv Detail & Related papers (2021-05-18T10:15:17Z)
This list is automatically generated from the titles and abstracts of the papers in this site.
This site does not guarantee the quality of this site (including all information) and is not responsible for any consequences.